RIPLEY, MS —
OSHA Inspection: INDUSTRIAL TIMBER, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of INDUSTRIAL TIMBER, LLC in 781 COUNTY ROAD 549, RIPLEY, MS 38663 (NAICS 337122). OSHA activity number 343980611.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INDUSTRIAL TIMBER, LLC
- Site address
- 781 COUNTY ROAD 549
- City
- RIPLEY
- State
- MS
- ZIP
- 38663
- Mailing
- 129 CHERTSEY DRIVE, MOORESVILLE, NC 28115
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337122
- Employees
- 124
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.212 A01
- Issued
- Jun 20, 2019
- Abate by
- Aug 5, 2019
- Penalty
- Initial $13,260 · Current $9,900 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Optimizer 1 - On or about April 30, 2019 the employer did not provide adequate guarding for the saw blade on the Optimizer, exposing employees to amputation hazards. (b) Optimizer 2 - On or about April 30, 2019 the employer did not provide adequate guarding for the saw blade on the Optimizer, exposing employees to amputation hazards. (c) Optimizer 3 - On or about April 30, 2019 the employer did not provide adequate guarding for the saw blade on the Optimizer, exposing employees to amputation hazards.
Recent events (2)
- — I (S) $9900
- — Z (S) $13260
1910.219 C02 I
- Issued
- Jun 20, 2019
- Abate by
- Aug 5, 2019
- Penalty
- Initial $9,472 · Current $9,472
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: (a) Vacuum pumps outside main building - On or about April 30, 2019, the employer did not provide adequate guarding for the rotating drive shafts of two vacuum pumps were not guarded. Employees that clean and provide maintenance are exposed to being caught-in the unguarded rotating drive shafts.
Recent events (2)
- — I (S) $9472
- — Z (S) $9472
1910.219 C04 I
- Issued
- Jun 20, 2019
- Abate by
- Aug 5, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft. (a) Planer/Rip Facility - On or about April 30, 2019, The employer did not ensure that a rotating shaft end at the end of transfer conveyor was adequately guarded, exposing employees to a caught-in hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 F03
- Issued
- Jun 20, 2019
- Abate by
- Aug 5, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: (a) Planer/Rip Facility - On or about April 30, 2019 the employer did not ensure the drive chain and sprocket was adequately guarded at the end of transfer conveyor, exposing employees to a caught-in hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.252 B02 III
- Issued
- Jun 20, 2019
- Abate by
- Jul 22, 2019
- Penalty
- Initial $5,683 · Current $0 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields or required to wear protective goggles. (a) Facility - On or about April 30, 2019, the employer did not provide adequate protection for employees working near arc welding rays, exposing employees to eye hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $5683
1910.303 F02
- Issued
- Jun 20, 2019
- Abate by
- Aug 5, 2019
- Penalty
- Initial $9,472 · Current $9,472
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: (a) Planer/Rip Saw Building. North and West Wall - On or about April 30, 2019 the employer did not ensure that electrical disconnects were adequately marked to indicate their purpose preventing employees from correctly identifying the electrical disconnects that controlled the equipment, exposing employees to fire hazards and amputation. (b) Main Production Building. South Wall - On or about April 30, 2019 the employer did not ensure that electrical disconnects were adequately marked to indicate their purpose preventing employees from correctly identifying the electrical disconnects that controlled the equipment, exposing employees to fire hazards and amputation.
Recent events (2)
- — I (S) $9472
- — Z (S) $9472
1910.22 A01
- Issued
- Jun 20, 2019
- Abate by
- Jul 22, 2019
- Penalty
- Initial $47,360 · Current $6,250 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms shall be kept clean and orderly and in a sanitary condition. (a) Planer/Rip Facility North Wall - On or about April 30, 2019 the employer did not ensure aisles and passageway to critical equipment disconnects were kept clean and passable exposing employees to trip hazards when attempting to access the electrical panels for performing energy control procedures. Industrial Timber, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.22(a)(1)), which was contained in OSHA inspection number 1162197, citation number 01, item number 001 and was affirmed as a final order on September 07, 2016, with respect to a workplace located at 781 CR 549 in Ripley, MS 38663.
Recent events (2)
- — I (S) $6250
- — Z (R) $47360
1910.305 B01 II
- Issued
- Jun 20, 2019
- Abate by
- Jul 22, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed (a) Main Building South Wall - On or about April 30, 2019, the employer did not ensure openings in the top of a 240 volt control panel were closed in a heavy wood dust environment, exposing employees to a fire hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Industrial Timber, LLC
View Industrial Timber, LLC's full OSHA safety record →
More inspections in this industry (NAICS 337122)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343980611.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.