Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: GILDAN YARNS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GILDAN YARNS, LLC in 3312 THIRD AVENUE, COLUMBUS, GA 31904 (NAICS 313110). OSHA activity number 343981973.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gildan Yarns, LLC for free Get an email when a new federal OSHA severe-injury report for Gildan Yarns, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
GILDAN YARNS, LLC
Site address
3312 THIRD AVENUE
City
COLUMBUS
State
GA
ZIP
31904
Mailing
2121 HEILIG ROAD, SALISBURY, NC 28146
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
313110
Employees
130
Ownership type
Private (A)

2 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 23, 2019
Abate by
Nov 4, 2019
Penalty
Initial $13,260 · Current $7,956 Reduced
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy:    (A)  A specific statement of the intended use of the procedure;  (B)  Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy;  (C)  Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; and  (D)  Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.      (a) Spinning Room Henri Gate System: On or before April 24, 2019, and at times prior, the employer exposed employees to caught-in hazards in that the employer did not have a specific procedure to lockout the Henri Gate System when performing duties associated with clearing jams, rearranging the push pins, and adjusting the conveyor belt for the machine.
Recent events (2)
  • · I (S) $7956
  • · Z (S) $13260

1910.147 C07 I A

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 23, 2019
Abate by
Nov 4, 2019
Penalty
Initial $13,260 · Current $7,956 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:      a) Spinning Room Henri Gate System: On or about April 24, 2019, and at times prior, the employer exposed employees to caught-in hazards in that the employer did not provide authorized employees the demonstration portion of LOTO training for the Henri Gate System or the Doffers before requiring the employees to work on them.
Recent events (2)
  • · I (S) $7956
  • · Z (S) $13260

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343981973.