Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PREMIER PAN COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PREMIER PAN COMPANY, INC. in 33 MCGOVERN BOULEVARD, CRESCENT, PA 15046 (NAICS 332215). OSHA activity number 343985974.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Premier PAN Company, INC. — free Get an email when a new federal OSHA severe-injury report for Premier PAN Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
33 MCGOVERN BOULEVARD
City
CRESCENT
State
PA
ZIP
15046
Mailing
33 MCGOVERN BOULEVARD, CRESCENT, PA 15046
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332215
Employees
140
Ownership type
A

2 citations on file for this inspection.

1910.217 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 18, 2019
Abate by
Jul 8, 2019
Penalty
Initial $10,229 · Current $5,115 Reduced
29 CFR 1910.217(b)(13): Control system(s) of mechanical power press(es) were not constructed so that a failure within the system would not prevent the normal stopping action from being applied to the press when required, but would prevent initiation of a successive stroke until the failure is corrected.    (a) 854 Press, Model #8- 33 McGovern Boulevard, Crescent, PA: On or about April 12, 2019, the part revolution power press's brake failed causing the ram to fall and pin the operators hands between the ram and the dye set.
Recent events (3)
  • — F (S) $5115
  • — C (S) $10229
  • — Z (S) $10229

1910.217 B14 II

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Jun 18, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.217(b)(14)(ii): Brake system monitoring of mechanical power press(es) was not installed so that it indicated when the performance of the braking system had deteriorated to the extent that the safety distance was not maintained.  (a) 854 Press, Model #8- 33 McGovern Boulevard, Crescent, PA: On or about April 12, 2019, the part revolution power press's brake failed causing the ram to fall and pin the operators hands between the ram and the dye set; the brake system monitoring was not so installed to properly indicate a fault in the braking system.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View Premier PAN Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343985974.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.