PARK RIDGE, IL —
OSHA Inspection: G & L CONTRACTORS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of G & L CONTRACTORS, INC. in 600 W. TALCOTT, PARK RIDGE, IL 60068 (NAICS 238910). OSHA activity number 343989802.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- G & L CONTRACTORS, INC.
- Site address
- 600 W. TALCOTT
- City
- PARK RIDGE
- State
- IL
- ZIP
- 60068
- Mailing
- 7401 N. ST. LOUIS, SKOKIE, IL 60076
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.100 A
- Issued
- May 30, 2019
- Penalty
- Initial $3,031 · Current $1,750 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about May 7, 2019, employees were exposed to head injury while working in an excavation and around heavy machinery/equipment without protective helmets. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (S) $1750
- — Z (S) $3031
1926.404 B01 II
- Issued
- May 30, 2019
- Penalty
- Initial $3,031 · Current $1,750 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection: a) On or about May 7, 2019, employees were provided with electrical tools and equipment connected by cord and plug to a Titan Industrial portable generator, having 6250 watts of start-up power, without the use of ground fault circuit interrupters or an assured equipment grounding conductor program. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (S) $1750
- — Z (S) $3031
1926.651 K01
- Issued
- May 30, 2019
- Penalty
- Initial $4,546 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift: a) On or about May 7, 2019, the employer did not have a competent person conduct inspections prior to the start of work and as needed throughout the shift during trenching and excavation work. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (S) $2500
- — Z (S) $4546
1926.652 A01
- Issued
- May 30, 2019
- Penalty
- Initial $4,546 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c) of this section: a) On or about May 7, 2019, employees were exposed to cave-in and struck-by hazards while working in an excavation without being protected from cave-ins by adequate shoring, sloping, or other protective means when working along vertical excavation walls at a depth of approximately 10 feet, 11 inches. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (S) $2500
- — Z (S) $4546
1926.652 E01 II
- Issued
- May 30, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.652(e)(1)(ii): Support systems were not installed and removed in a manner that protected employees from cave-ins, structural collapses, or from being struck by members of the support system: a) On or about May 7, 2019, employees were exposed to struck-by and crushing hazards while installing plywood sheathing and angle iron during the construction of a support system installed along the east vertical exaction wall at a depth of approximately 10 feet, 11 inches. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at G & L Contractors, INC.
View G & L Contractors, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238910)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343989802.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.