Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CEASER CHIMNEY SERVICE, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CEASER CHIMNEY SERVICE, LLC in 36 FEDERAL STREET, CONCORD, NH 03301 (NAICS 238140). OSHA activity number 343989984.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ceaser Chimney Service, LLC — free Get an email when a new federal OSHA severe-injury report for Ceaser Chimney Service, LLC is published. One employer, no account, unsubscribe in one click.
Site address
36 FEDERAL STREET
City
CONCORD
State
NH
ZIP
03301
Mailing
750 E. INDUSTRIAL PARK DR. #5, MANCHESTER, NH 03109
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
9
Ownership type
A

4 citations on file for this inspection.

1926.100 A

Other-than-serious 1 instance 1 exposed
Issued
Jun 13, 2019
Abate by
Jun 19, 2019
Penalty
Initial $2,842 · Current $0 Reduced
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by wearing protective helmets:    a. Site - On or about May 7, 2019, employees engaged in material handling while standing directly underneath the scaffolding system were exposed to head injuries from falling or dropping materials,where hardhats were not provided or utilized to prevent the hazard.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2842

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 13, 2019
Abate by
Jun 19, 2019
Penalty
Initial $2,842 · Current $2,000 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used:    a. Site - On or about April 18, 2019, employees were not provided with safe means to and from the scaffolding system where a access ladder was not provided or utilized.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2842

1926.451 G01

Serious Gravity 10 2 instances 2 exposed
Issued
Jun 13, 2019
Abate by
Jun 19, 2019
Penalty
Initial $3,978 · Current $0 Reduced
29 CFR 1926.451(g)(1): 29 CFR 1926.451(g)(1):  Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level by fall protection established in accordance with paragraphs (g)(1)(i) through (vii) of this section:     a. Roof scaffolding system - On or about April 18, 2019, employees engaged in chimney activities were exposed to fall hazards where fall protection was not provided or utilized to prevent the fall hazard.        b. Three tier scaffolding system - On or about April 18, 2019, employees engaged in chimney activities were exposed to fall hazards where fall protection was not provided or utilized to prevent the fall of over 12 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3978

1926.451 G01 III

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 13, 2019
Abate by
Jun 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1)(iii): Each employee on a crawling board (chicken ladder) was not protected by a personal fall arrest system, a guardrail system (with minimum 200 pound toprail capacity), or by a three-fourth inch (1.9 cm) diameter grabline or equivalent handhold securely fastened beside each crawling board:    a. Site - On or about April 18, 2019, employees were exposed to fall hazards while navigating the chicken ladder for access to the roof scaffolding system where fall protection was not provided or utilized to prevent the fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Ceaser Chimney Service, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343989984.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.