SYRACUSE, NY —
OSHA Inspection: PROPERTY RESTORATION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PROPERTY RESTORATION, INC. in AARON MANOR, UNIT 13, GORDON PARKWAY, SYRACUSE, NY 13219 (NAICS 236118). OSHA activity number 343993218.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PROPERTY RESTORATION, INC.
- Site address
- AARON MANOR, UNIT 13, GORDON PARKWAY
- City
- SYRACUSE
- State
- NY
- ZIP
- 13219
- Mailing
- 6194 THOMPSON ROAD #8, SYRACUSE, NY 13206
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 20
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.403 I02 I
- Issued
- Jun 27, 2019
- Abate by
- Jul 8, 2019
- Penalty
- Initial $5,304 · Current $1,600 Reduced
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph: a) North side of building, Unit #13, on or about 5-8-19: One employee was pressure washing smoke residue from a brick wall using a metal spray wand, holding the wand within 16 inches of an unprotected energized service entrance. b) North side of building, Unit #13, on or about 5-8-19: One employee used his bare hands to remove plastic sheeting that had been draped over an unprotected energized service entrance, with his hands placed within 4 inches of the live line.
Recent events (3)
- — J (S) $1600
- — C (S) $5304
- — Z (S) $5304
1926.451 F03
- Issued
- Jun 27, 2019
- Abate by
- Jul 12, 2019
- Penalty
- Initial $3,789 · Current $800 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) North side of building, Unit #13, on or about 5-8-19: One employee was working on a "pick" type scaffold platform that was not inspected by a competent person, in that the platform ends were setting on the surface of two entry canopy roofs, exposing the employee to a fall hazard of 12 feet 9 inches to the pavement below.
Recent events (3)
- — J (S) $800
- — C (S) $3789
- — Z (S) $3789
1926.451 G01
- Issued
- Jun 27, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: a) North side of building, Unit #13, on or about 5-8-19: One employee was working on a "pick" type scaffold platform, without fall protection, exposing the employees to a fall hazard of 12 feet 9 inches.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Jun 27, 2019
- Penalty
- Initial $3,789 · Current $800 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system: a) North side of building, Unit #13, on or about 5-8-19: One employee was working on the ridge area of a sloped roof surface, 5:12 pitch, without fall protection, exposing the employee to a fall hazard of 13 feet 5 inches to the pavement below.
Recent events (3)
- — J (S) $800
- — C (S) $3789
- — Z (S) $3789
1926.1053 B01
- Issued
- Jun 27, 2019
- Penalty
- Initial $3,789 · Current $800 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) North side of building, Unit #13, on or about 5-8-19: One employee was using a ladder for access and egress from a roof surface with side rails that were even with the landing surface, exposing the employee to a fall hazard of 13 feet 5 inches to the pavement below.
Recent events (3)
- — J (S) $800
- — C (S) $3789
- — Z (S) $3789
More inspections at Property Restoration, INC.