Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: HARBOR VIEW HOTEL OWNER LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HARBOR VIEW HOTEL OWNER LLC in 131 NORTH WATER ST, EDGARTOWN, MA 02539 (NAICS 238990). OSHA activity number 343999603.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Harbor View Hotel Owner LLC for free Get an email when a new federal OSHA severe-injury report for Harbor View Hotel Owner LLC is published. One employer, no account, unsubscribe in one click.
Site address
131 NORTH WATER ST
City
EDGARTOWN
State
MA
ZIP
02539
Mailing
745 BOYLSTON ST. C/O UPLAND CAPITAL CORPORATION, BOSTON, MA 02116
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
3
Ownership type
Private (A)

1 citation on file for this inspection.

1926.20 B02

Serious Gravity 10 5 instances 25 exposed
Issued
Jul 3, 2019
Penalty
Initial $5,304 · Current $3,713 Reduced
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person  Location: Harborview Hotel, Mayhew Building, N.Water St. Edgartown, Martha's Vineyard, MA  On May 6th, 2019, employees were exposed to falls hazards, struck by hazards, electrical shock hazards, and caught between hazards where frequent and regular inspections made by a competent person did not identify and mitigate the hazards:   Instances:  a) Scaffold above the entryway in the rear of the building was inadequately erected and not inspected by a competent person. b) Siders and framers were working above the entryway and around the exterior of the building and head protection was not utilized throughout the project c) The exterior decks used as an entryway on the 2nd and 3rd floor in the rear of the building did not have guard rails installed d) Temporary lighting inside the building was missing bulbs  e) Fire extinguishers were not inspected and/or inoperable in the building
Recent events (2)
  • · I (S) $3712.8
  • · Z (S) $5304

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343999603.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.