EDGARTOWN, MA ·
OSHA Inspection: HARBOR VIEW HOTEL OWNER LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HARBOR VIEW HOTEL OWNER LLC in 131 NORTH WATER ST, EDGARTOWN, MA 02539 (NAICS 238990). OSHA activity number 343999603.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HARBOR VIEW HOTEL OWNER LLC
- Site address
- 131 NORTH WATER ST
- City
- EDGARTOWN
- State
- MA
- ZIP
- 02539
- Mailing
- 745 BOYLSTON ST. C/O UPLAND CAPITAL CORPORATION, BOSTON, MA 02116
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 3
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
1926.20 B02
- Issued
- Jul 3, 2019
- Penalty
- Initial $5,304 · Current $3,713 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person Location: Harborview Hotel, Mayhew Building, N.Water St. Edgartown, Martha's Vineyard, MA On May 6th, 2019, employees were exposed to falls hazards, struck by hazards, electrical shock hazards, and caught between hazards where frequent and regular inspections made by a competent person did not identify and mitigate the hazards: Instances: a) Scaffold above the entryway in the rear of the building was inadequately erected and not inspected by a competent person. b) Siders and framers were working above the entryway and around the exterior of the building and head protection was not utilized throughout the project c) The exterior decks used as an entryway on the 2nd and 3rd floor in the rear of the building did not have guard rails installed d) Temporary lighting inside the building was missing bulbs e) Fire extinguishers were not inspected and/or inoperable in the building
Recent events (2)
- · I (S) $3712.8
- · Z (S) $5304