ARNOLD A F B, TN —
OSHA Inspection: PEN GULF INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PEN GULF INC in BUILDING 780 AVE "C" ARNOLD ENGINEERING DEVELOPMENT CENTER, ARNOLD A F B, TN 37389 (NAICS 811310). OSHA activity number 344005038.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PEN GULF INC
- Site address
- BUILDING 780 AVE "C" ARNOLD ENGINEERING DEVELOPMENT CENTER
- City
- ARNOLD A F B
- State
- TN
- ZIP
- 37389
- Mailing
- PO BOX 12916, PENSACOLA, FL 32591
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811310
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.134 H02 I
- Issued
- Oct 24, 2019
- Abate by
- Oct 30, 2019
- Penalty
- Initial $6,819 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(h)(2)(i): All respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals, and they shall be packed or stored to prevent deformation of the facepiece and exhalation valve. a) Arnold Air Force Base, Building 780 "C" Avenue storage/utility trailer, on or about 8 May 2019, two half-face elastomeric air purifying respirators were sitting in the open with other equipment in a cardboard box.
Recent events (2)
- — I (O) $0
- — Z (S) $6819
1926.152 B02
- Issued
- Oct 24, 2019
- Abate by
- Oct 30, 2019
- Penalty
- Initial $6,819 · Current $0 Reduced
General-duty citation text
29 CFR 1926.152(b)(2): Quantities of flammable and combustible liquid in excess of 25 gallons were not stored in an acceptable or approved cabinet. a) Arnold Air Force Base, Building 780 Avenue "C" - storage/utility trailer, on or about 8 May 2019, containers containing flammable liquids including but not limited to Sherwin Williams Protective and Marine Coating, Klean Strip Adhesive Remover, Crown Denatured Alcohol, petroleum gasoline in excess of 25 gallons were not stored as required.
Recent events (2)
- — I (S) $0
- — Z (S) $6819
More inspections at PEN Gulf INC