Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: ADONIS ROOFING INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ADONIS ROOFING INC. in 8884 CONNEMARA LANE, CLARENCE CENTER, NY 14032 (NAICS 238160). OSHA activity number 344005806.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Adonis Roofing INC. for free Get an email when a new federal OSHA severe-injury report for Adonis Roofing INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ADONIS ROOFING INC.
Site address
8884 CONNEMARA LANE
City
CLARENCE CENTER
State
NY
ZIP
14032
Mailing
25 LIANNE DRIVE, ROCHESTER, NY 14626
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
Private (A)

3 citations on file for this inspection.

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
May 30, 2019
Penalty
Initial $2,273 · Current $1,000 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used:      a) On or about 5/6/19, on a roofing jobsite, at a house located at 8884 Connemara Lane, Clarence Center, NY: A Ladder Jack Scaffold was erected on the back left side of the house. The scaffold had two support ladders, and the brackets that supported the aluminum pik were on the outside (the side away from the house) of the ladder. Employees used the scaffold to access & exit the roof.  The employee stepped down from the roof onto the pik, climbed down and over the bracket on either of the support ladders. A separate access ladder from the pik to the ground was not provided.      NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2273

1926.501 B11

Serious Gravity 5 1 instance 2 exposed
Issued
May 30, 2019
Penalty
Initial $2,842 · Current $2,000 Reduced
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:      a) On or about 5/6/19, on a roofing jobsite, at a house located at 8884 Connemara Lane, Clarence Center, NY: One employee was engaged in roofing work on the steep roof on the front right side of the house, and a second employee was engaged in roofing work on the steep roof on the back side of the house. The employees were exposed to a fall of approx. 18 ft. because fall protection was not being utilized. Pitch of the roof was approx. 8 in 12.      NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • · I (S) $2000
  • · Z (S) $2842

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
May 30, 2019
Penalty
Initial $2,273 · Current $1,500 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:      a) On or about 5/6/19, on a roofing jobsite, at a house located at 8884 Connemara Lane, Clarence Center, NY: In order to access & exit the front roof, employees climbed a Little Giant type extension ladder that had been set up on the ground. The siderails of that extension ladder were approx. 20 inches above the roof.       NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • · I (S) $1500
  • · Z (S) $2273

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344005806.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.