Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UNITED STATES POSTAL SERVICE

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of UNITED STATES POSTAL SERVICE in 119 CENTER STREET EAST, MADISON, SD 57042 (NAICS 491110). OSHA activity number 344020185.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch United States Postal Service — free Get an email when a new federal OSHA severe-injury report for United States Postal Service is published. One employer, no account, unsubscribe in one click.
Site address
119 CENTER STREET EAST
City
MADISON
State
SD
ZIP
57042
Mailing
PO BOX 7560, SIOUX FALLS, SD 57117
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Case closed
Last modified
Data loaded
NAICS code
491110
Employees
12
Ownership type
A

6 citations on file for this inspection.

1910.303 F02

Serious Gravity 1 1 instance 7 exposed
Issued
Oct 25, 2019
Abate by
Nov 21, 2019
Penalty
Initial $2,501 · Current $2,000 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    (a)United States Postal Service at 119 Center Street East, Madison, SD 57042: On or about and at times prior to May 14, 2019, the employer did not ensure employees were protected from electrical hazards in that the breakers on panel B-1 were not marked to indicate their purpose and not located and arranged so the purpose was evident. This condition exposed employees to the hazard of electrical shock and burns.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2501

1910.303 G01 I

Other-than-serious 1 instance 7 exposed
Issued
Oct 25, 2019
Abate by
Nov 21, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(i): Working space for equipment likely to require examination, adjustment, servicing, or maintenance while energized shall comply with the following dimensions, except as required or permitted elsewhere in this subpart:    (a)United States Postal Service at 119 Center Street East, Madison, SD 57042: On or about and at times prior to May 14, 2019, the employer did not ensure employees were protected from electrical hazards in that clearance around the electrical panel B-1 was less than that specified in Table S-1. Clearance space to the B-1 electrical panel in the basement was impeded by vehicle tires stored in front of the panel. This condition exposed employees to the hazard of electrical shock and burns.    Abatement Note:    (A)The depth of the working space in the direction of access to live parts may not be less than indicated in Table S-1. Distances shall be measured from the live parts if they are exposed or from the enclosure front or opening if they are enclosed;  (B)The width of working space in front of the electric equipment shall be the width of the equipment or 762 mm (30 in.), whichever is greater. In all cases, the working space shall permit at least a 90-degree opening of equipment doors or hinged panels; and  (C)The work space shall be clear and extend from the grade, floor, or platform to the height required by paragraph (g)(1)(vi) of this section. However, other equipment associated with the electrical installation and located above or below the electric equipment may extend not more than 153 mm (6 in.) beyond the front of the electric equipment.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.305 B01

Serious Gravity 1 1 instance 7 exposed
Issued
Oct 25, 2019
Abate by
Nov 21, 2019
Penalty
Initial $2,501 · Current $2,000 Reduced
29 CFR 1910.305(b)(1): Unused openings in boxes, cabinets, or fittings were not effectively closed:    (a)United States Postal Service at 119 Center Street East, Madison, SD 57042: On or about and at times prior to May 14, 2019, the employer did not ensure unused openings in an electrical junction box were effectively closed. Two knockout plugs were missing on the junction box between the scale and the west bay door in the vestibule, exposing live electrical parts. This condition exposed employees to electrical shock and burns.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2501

1910.1025 L01 I

Deleted Serious Gravity 1 1 instance 3 exposed
Issued
Oct 25, 2019
Abate by
Nov 21, 2019
Penalty
Initial $2,501 · Current $0 Reduced
29 CFR 1910.1025(l)(1)(i): Employees working in an area where there is potential exposure to airborne lead at any level were not informed of the content of Appendices A and B of 29 CFR 1910.1025:  (a)United States Postal Service at 119 Center Street East, Madison, SD 57042: On or about and at times prior to May 14, 2019, the employer did not ensure employees were protected from hazards associated with lead exposure in that employees were required to perform housekeeping activities that included removal of lead-containing paint chips and were not informed of the content of Appendices A and B of 29 CFR 1910.1025. This condition exposed employees to hazards associated with lead exposure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2501

1910.37 B06

Deleted Other-than-serious 1 instance 2 exposed
Issued
Oct 25, 2019
Abate by
Nov 21, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(6): Each exit sign must be illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color. Self-luminous or electroluminescent signs that have a minimum luminance surface value of at least .06 footlamberts (0.21 cd/m2) are permitted:   (a)United States Postal Service at 119 Center Street East, Madison, SD 57042: On or about and at times prior to May 14, 2019, the employer did not ensure employee were protected from hazards associated with emergency egress in that the exit signs in the Postmasters office were not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source or have a minimum luminance surface value of at least .06 footlamberts for electroluminescent signs. This condition exposed employees to hazards associated with emergency egress.  (b)United States Postal Service at 119 Center Street East, Madison, SD 57042: On or about and at times prior to May 14, 2019, the employer did not ensure employee were protected from hazards associated with emergency egress in that the exit sign on the east side of the lobby was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source or have a minimum luminance surface value of at least .06 footlamberts for electroluminescent signs. This condition exposed employees to hazards associated with emergency egress.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1001 J07 IV

Deleted Other-than-serious 1 instance 3 exposed
Issued
Oct 25, 2019
Abate by
Nov 21, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1001(j)(7)(iv): The employer did not provide to all employees who perform housekeeping work in areas where ACM and/or PACM is present, an asbestos awareness training course covering the health effects of asbestos; and/or locations of ACM and/or recognition of ACM and PACM damage and deterioration and/or requirements in this standard related to housekeeping, and/or proper response to fiber release episodes:  (a)United States Postal Service at 119 Center Street East, Madison, SD 57042: On or about and at times prior to May 14, 2019, the employer did not ensure employees were protected from hazards related to asbestos exposure. Employees were required to perform housekeeping activities where ACM and/or PACM were located and not provided an asbestos awareness training course covering the health effects of asbestos; and/or locations of ACM and/or recognition of ACM and PACM damage and deterioration and/or requirements in this standard related to housekeeping, and/or proper response to fiber release episodes. This condition exposed employees to hazards related to asbestos exposure.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View United States Postal Service's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344020185.