SHREVEPORT, LA —
OSHA Inspection: AEON PROCESS EQUIPMENT & CONTROLS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AEON PROCESS EQUIPMENT & CONTROLS in 505 AERO DR., SHREVEPORT, LA 71107 (NAICS 333512). OSHA activity number 344020870.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AEON PROCESS EQUIPMENT & CONTROLS
- Site address
- 505 AERO DR.
- City
- SHREVEPORT
- State
- LA
- ZIP
- 71107
- Mailing
- 505 AERO DR., SHREVEPORT, LA 71107
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333512
- Employees
- 20
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A02
- Issued
- Oct 31, 2019
- Abate by
- Nov 15, 2019
- Penalty
- Initial $3,789 · Current $3,789
General-duty citation text
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible: a) On or about May 16, 2019, inside the Valve Shop Area, a point of operation guard was not properly affixed to the Drill press (Jet, Model: J DP-17MF, Ser: 10916904). b) On or about May 16, 2019, inside the Rear Repair Area, a point of operation guard was not properly affixed to the Mill (Rigid, Model SB1024).
Recent events (2)
- — I (O) $3789
- — Z (S) $3789
1910.212 B
- Issued
- Oct 31, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) On or about May 16, 2019, inside the Valve Shop Area, the Drill press (Jet Tools, Model: J DP-17MF, Ser: 10916904) was not properly affixed to the floor. b) On or about May 16, 2019, inside the Rear Repair Area, the Bench Grinder (Jet Tools, Model JBG-3A) was not properly affixed to the floor. c) On or about May 16, 2019, inside the Rear Repair Area, the Mill (Rigid, Model SB1024) was not properly affixed to the floor.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Aeon Process Equipment & Controls
View Aeon Process Equipment & Controls's full OSHA safety record →
More inspections in this industry (NAICS 333512)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344020870.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.