LOS ALAMITOS, CA —
OSHA Inspection: U.S. PROPERTY FISCAL OFFICE DET 1
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of U.S. PROPERTY FISCAL OFFICE DET 1 in 11302 INDEPENDENCE ROAD BLDG. 920B, LOS ALAMITOS, CA 90720 (NAICS 493110). OSHA activity number 344022173.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. PROPERTY FISCAL OFFICE DET 1
- Site address
- 11302 INDEPENDENCE ROAD BLDG. 920B
- City
- LOS ALAMITOS
- State
- CA
- ZIP
- 90720
- Mailing
- 11302 INDEPENDENCE ROAD BLDG. 920B, LOS ALAMITOS, CA 90720
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 11
- Ownership type
- D
Citations
2 citations on file for this inspection.
1960.8 A
- Issued
- Jul 10, 2019
- Abate by
- Aug 31, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1960.8(a): The Agency head did not furnish employment and a place of employment to each employee that were free from recognized hazards that caused or were likely to cause death or serious physical harm: (a) On or about March 12, 2019 and at times prior to that date, for the employees exposed to crushing hazards while loading/unloading industrial rack systems where the base plates were not anchored to the floor with anchor bolts in the CIF Warehouse located at 11302 Independence Road, Bldg. 920B, Los Alamitos, California.. Among other methods, one feasible and acceptable means to correct the hazard is to follow the requirements of ANSI MH16.1 section 1-1.4.7 states that the bottom of all columns shall be furnished with column base plates, as specified in Section 7.1. All rack columns shall be anchored to the floor with anchor bolts, which shall be designed in accordance with Section 7.3, to resist all applicable forces as described in Section 2.1 or Section 2.2.
Recent events (1)
- — Z (S) $0
1910.28 B01 I
- Issued
- Jul 10, 2019
- Abate by
- Aug 31, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet or more above a lower level is protected from falling. (a) On or about March 12, 2019 and at times prior to that date, for the employees exposed to fall hazards where the dock area was 48 inches or greater from ground level at the CIF building located at 11302 Independence Road, Bldg. 920B, Los Alamitos, California.
Recent events (1)
- — Z (S) $0
More inspections at U.S. Property Fiscal Office DET 1
View U.S. Property Fiscal Office DET 1's full OSHA safety record →
More inspections in this industry (NAICS 493110)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344022173.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.