Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BRIGADE ENERGY SERVICES LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of BRIGADE ENERGY SERVICES LLC in P PETERSON 155-99-3-15-22-14H, WILLISTON, ND 58802 (NAICS 213112). OSHA activity number 344027016.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Brigade Energy Services LLC — free Get an email when a new federal OSHA severe-injury report for Brigade Energy Services LLC is published. One employer, no account, unsubscribe in one click.
Site address
P PETERSON 155-99-3-15-22-14H
City
WILLISTON
State
ND
ZIP
58802
Mailing
700 17TH STREET SUITE 1550, DENVER, CO 80202
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
547
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Oct 28, 2019
Abate by
Nov 1, 2019
Penalty
Initial $13,260 · Current $0 Reduced
Section (5)(a)(1): The employer failed to furnish to each of his employees employment and a place of employment which was free from recognized hazards that were causing or are likely to cause death or serious physical harm, in that employees were exposed to struck-by hazards:    (a) On May 18, 2019, and at times prior, where the employer failed to ensure employees were protected from struck-by hazards in that sucker rod couplings were used to connect to a polished rod. During the tripping-in process, the mismatched connection caused the polished rod to come free from the sucker rod, fall from its elevated location above the wellhead, and strike an employee, causing fatal injuries near Well site P Peterson 155-99-3-15-22-14H near Williston, North Dakota.  Abatement note: Among other feasible and useful means of abatement, the employer can follow the API 11B, API 54, and API 11BR recommendation to ensure that sucker rod couplings are not used on a polished rod and to inspect the couplings to make sure the connections are tightened.
Recent events (3)
  • — J (S) $0
  • — C (S) $13260
  • — Z (S) $13260

View Brigade Energy Services LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344027016.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.