BROOKLYN, NY —
OSHA Inspection: AD COMPLETE CONSTRUCTION INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AD COMPLETE CONSTRUCTION INC in 3087 OCEAN AVE., BROOKLYN, NY 11235 (NAICS 236220). OSHA activity number 344033436.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AD COMPLETE CONSTRUCTION INC
- Site address
- 3087 OCEAN AVE.
- City
- BROOKLYN
- State
- NY
- ZIP
- 11235
- Mailing
- 100-04 31ST AVE. 1ST FL., EAST ELMHURST, NY 11369
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.404 B01 I
- Issued
- Nov 13, 2019
- Abate by
- Nov 20, 2019
- Penalty
- Initial $2,842 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. a) Ground floor, building front entrance: An employee used an electric powered circular saw to do carpentry work. The circular saw was connected to an extension cord, which was routed to a nearby outlet device and was not provided with a ground fault circuit interrupter. On or about 05/24/19.
Recent events (2)
- — I (S) $1500
- — Z (S) $2842
1926.405 G02 III
- Issued
- Nov 13, 2019
- Abate by
- Nov 20, 2019
- Penalty
- Initial $2,842 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap. a) Ground floor, building front entrance: An employee used an electric powered circular saw to do carpentry work. The circular saw's power cord was spliced to another flexible cord. On or about 05/24/19.
Recent events (2)
- — I (S) $1500
- — Z (S) $2842
1926.416 E01
- Issued
- Nov 13, 2019
- Abate by
- Nov 20, 2019
- Penalty
- Initial $2,842 · Current $0 Reduced
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used. a) Ground floor, building front entrance: An employee used an electric powered circular saw to do carpentry work. The circular saw was connected to an extension cord, which was worn and frayed with damaged insulation. On or about 05/24/19.
Recent events (2)
- — I (S) $0
- — Z (S) $2842
More inspections at AD Complete Construction INC
View AD Complete Construction INC's full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344033436.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.