AURORA, CO —
OSHA Inspection: GOODWILL INDUSTRIES OF DENVER# 5182
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of GOODWILL INDUSTRIES OF DENVER# 5182 in 10590 EAST COLFAX AVE, AURORA, CO 80010 (NAICS 448140). OSHA activity number 344036249.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GOODWILL INDUSTRIES OF DENVER# 5182
- Site address
- 10590 EAST COLFAX AVE
- City
- AURORA
- State
- CO
- ZIP
- 80010
- Mailing
- 10590 EAST COLFAX AVE, AURORA, CO 80010
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 448140
- Employees
- 27
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.1001 J03 III
- Issued
- Aug 19, 2019
- Abate by
- Sep 20, 2019
- Penalty
- Initial $4,831 · Current $2,416 Reduced
General-duty citation text
29 CFR 1910.1001(j)(3)(iii): The employer did not inform employees who performed housekeeping activities in areas having presumed asbestos-containing material (PACM) and /or other asbestos-containing material (ACM) of the presence and/or location of PACM and/or other ACM in such areas which might be contacted during such activities: a) On or about May 20, 2019, and at times prior, the employer did not inform employees of the presence, location, and quantity of asbestos containing material where production and housekeeping activities such as dry sweeping occur. This condition exposed employees to an asbestos respiratory hazard that could result in chronic restrictive lung disease, asbestosis, lung cancer, and mesothelioma. Abatement note: Abatement certification and documentation are required for this item (See Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $2415.5
- — Z (S) $4831
1910.1001 J04 IV
- Issued
- Aug 19, 2019
- Abate by
- Sep 20, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1001(j)(4)(iv): At the entrance to mechanical rooms/areas in which employees reasonably can be expected to enter and which contain ACM and/or PACM, the building owner did not post signs which identify the material which is present, its location, and appropriate work practices which, if followed, will ensure that ACM and/or PACM will not be disturbed: a) On or about May 20, 2019, and at times prior, the employer did not ensure that employees working in areas containing ACM were notified by the use of signs indicating the presence and location of asbestos in the work area. This condition exposed employees to an asbestos respiratory hazard that could result in chronic restrictive lung disease, asbestosis, lung cancer, and mesothelioma. Abatement note: Abatement certification is required for this item (See Certification of Corrective Action worksheet).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1001 J07 IV
- Issued
- Aug 19, 2019
- Abate by
- Sep 20, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1001(j)(7)(iv): The employer did not provide, at no cost to employees who perform housekeeping operations in an area which contains presumed asbestos-containing material (PACM) and/or other asbestos-containing material (ACM), an asbestos awareness training course: a) On or about May 20, 2019, and at times prior, the employer did not ensure that employees performing housekeeping activities such as dry sweeping, cleaning, and moving and arranging merchandise in the production area were provided asbestos awareness training. This condition exposed employees to an asbestos respiratory hazard that could result in chronic restrictive lung disease, asbestosis, lung cancer, and mesothelioma. Abatement Note: Abatement certification and documentation are required for this item (See Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1001 K08
- Issued
- Aug 19, 2019
- Abate by
- Sep 20, 2019
- Penalty
- Initial $4,831 · Current $2,416 Reduced
General-duty citation text
29 CFR 1910.1001(k)(8): The employer cleaned up waste and debris and accompanying dust in an area containing accessible or visibly deteriorated ACM and/or PACM, by dry dusting, dry sweeping or vacuuming without using high-efficiency particulate air filters: a) On or about May 20, 2019, and at times prior, the employer did not ensure that employees did not dry sweep visibly deteriorated floor containing asbestos. This condition exposed employees to an asbestos respiratory hazard that could result in chronic restrictive lung disease, asbestosis, lung cancer, and mesothelioma. Abatement note: Abatement certification is required for this item (See Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $2415.5
- — Z (S) $4831
More inspections in this industry (NAICS 448140)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344036249.