Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INNOVATIVE WALL SOLUTIONS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of INNOVATIVE WALL SOLUTIONS, LLC in 20200 POPLAR CREEK PARKWAY, BROOKFIELD, WI 53045 (NAICS 238990). OSHA activity number 344039318.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Innovative Wall Solutions, LLC — free Get an email when a new federal OSHA severe-injury report for Innovative Wall Solutions, LLC is published. One employer, no account, unsubscribe in one click.
Site address
20200 POPLAR CREEK PARKWAY
City
BROOKFIELD
State
WI
ZIP
53045
Mailing
237 S. CURTIS ROADS, WEST ALLIS, WI 53214
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
12
Ownership type
A

7 citations on file for this inspection.

1926.451 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 3, 2019
Abate by
Jul 10, 2019
Penalty
Initial $5,304 · Current $2,652 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)  (a) On the scaffold system located at the worksite located at 20200 Poplar Creek Parkway, Brookfield, WI, the employer did not ensure all sections where employees were working had full planking, thereby exposing workers to fall hazards.
Recent events (2)
  • — I (S) $2652
  • — Z (S) $5304

1926.451 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 3, 2019
Abate by
Jul 10, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:  (a) At the worksite located at 20200 Poplar Creek Parkway, Brookfield, WI, the employer did not ensure a scaffold had a complete guardrail system near access points. There was a ladder installed within the scaffold system but the area around the access points did not have adequate fall protection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G04 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 3, 2019
Abate by
Jul 10, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(4)(iv): Midrails were not installed at a height approximately midway between the top edge of the guardrail system and the platform surface:  (a) At the worksite located at 20200 Poplar Creek Parkway, Brookfield, WI, the employer did not ensure mid rails were installed in all locations where employees were working, thereby exposing workers to fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 H01

Serious Gravity 1 4 instances 1 exposed
Issued
Jul 3, 2019
Abate by
Jul 10, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.451(h)(1): 29 CFR 1926.451(h)(1): In addition to wearing hardhats each employee on a scaffold shall be provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, or guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects.  (a) At the worksite located at 20200 Polar Creek Parkway, Brookfield, WI, the employer did not ensure employees were using head protection in addition other methods such as toe boards, screens, etc. to protect employees working below material, equipment and personnel, thereby exposing workers to struck-by hazards.    ...in the alternative...  29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  (a) At the worksite located at 20200 Polar Creek Parkway, Brookfield, WI, the employer did not ensure employees were using head protection when conducting work from a scaffold system, thereby exposing workers to struck-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 C03

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 3, 2019
Abate by
Aug 20, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.454(c)(3): When inadequacies in an affected employee's knowledge of use of fall protection systems or equipment indicate that the employee has not retained the requisite understanding or skill, the employer shall retrain the affected employee.  (a) The employer did not ensure employees had received adequate training in recognizing fall hazards and implementing fall protection when conducting work from a scaffold system, thereby being exposed to fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 3, 2019
Abate by
Jul 10, 2019
Penalty
Initial $5,304 · Current $2,652 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  (a) At the worksite located at 20200 Poplar Creek Parkway, Brookfield, WI, the employer did not ensure employees were using fall protection when installing EFIS material from a balcony surface, thereby exposing workers to fall hazards.
Recent events (2)
  • — I (S) $2652
  • — Z (S) $5304

1926.503 C03

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 3, 2019
Abate by
Aug 20, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.503(c)(3): The employer did not retrain affected employees who already had been trained but demonstrated inadequate understanding and skill required by paragraph (a) of this section:  (a) The employer did not ensure employees had received adequate training in recognizing fall hazards and implementing fall protection when conducting exterior work on commercial and residential buildings, thereby being exposed to fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Innovative Wall Solutions, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344039318.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.