NEW BRAUNFELS, TX —
OSHA Inspection: HAROS BROTHER COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HAROS BROTHER COMPANY in MORNINGSIDE DR AND HIGHLAND VISTA, NEW BRAUNFELS, TX 78130 (NAICS 237130). OSHA activity number 344040498.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HAROS BROTHER COMPANY
- Site address
- MORNINGSIDE DR AND HIGHLAND VISTA
- City
- NEW BRAUNFELS
- State
- TX
- ZIP
- 78130
- Mailing
- 7514 MANSFIELD HWY, KENNEDALE, TX 76060
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237130
- Employees
- 100
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.652 C02 I
- Issued
- Jul 1, 2019
- Abate by
- Jul 8, 2019
- Penalty
- Initial $3,978 · Current $2,387 Reduced
General-duty citation text
29 CFR 1926.652(c)(2)(i): Design of support systems, shield systems, or other protective systems that are drawn from manufacturer's tabulated data were not in accordance with all specifications, recommendations, and limitations issued or made by the manufacturer: On or about May 29, 2019, at the site, the employer failed to ensure the trench box was placed properly in accordance with the Xterra Trench shield tabulated data. The trench box was below the soil approximately 18 inches where employees were installing PVC pipe. Employees exposed to the hazard of being struck-by falling soil/rocks.
Recent events (2)
- — I (S) $2386.8
- — Z (S) $3978
1926.652 A01
- Issued
- Jul 1, 2019
- Abate by
- Jul 8, 2019
- Penalty
- Initial $6,630 · Current $3,978 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c): On or about May 28, 2019, at the site, the employer failed to ensure the employees were protected from cave-ins by an adequate protective system. Employees were installing communication lines outside the trench box which ranged in depth from approximately 6 feet to 8 feet. Employees exposed to cave-in hazards.
Recent events (2)
- — I (S) $3978
- — Z (S) $6630
More inspections in this industry (NAICS 237130)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344040498.