OSHA Inspection: WISCONSIN PAINT AND POWDER COAT

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WISCONSIN PAINT AND POWDER COAT in 825 W MAIN ST, SUITE B, HORTONVILLE, WI 54944 (NAICS 332812). OSHA activity number 344041660.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wisconsin Paint and Powder Coat — free Get an email when a new federal OSHA severe-injury report for Wisconsin Paint and Powder Coat is published. One employer, no account, unsubscribe in one click.
Site address
825 W MAIN ST, SUITE B
City
HORTONVILLE
State
WI
ZIP
54944
Mailing
825 W MAIN ST, SUITE B, HORTONVILLE, WI 54944
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
15
Ownership type
A

12 citations on file for this inspection.

1910.23 B01

Serious Gravity 5 3 instances 1 exposed
Issued
Oct 29, 2019
Penalty
Initial $3,031 · Current $1,819 Reduced
29 CFR 1910.23(b)(1): (1) Ladder rungs, steps, and cleats are parallel, level, and uniformly spaced when the ladder is in position for use.    On or about May 29, 2019, fixed ladders leading to the access platforms 1, 2 and 3 for the Five Stage Parts Washer did not maintain uniform spacing between rungs.
Recent events (2)
  • — I (S) $1818.6
  • — Z (S) $3031

1910.28 B03 IV

Serious Gravity 5 3 instances 1 exposed
Issued
Oct 29, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.28(b)(3)(iv): (iv) Each employee is protected from falling into a ladderway floor hole or ladderway platform hole by a guardrail system and toeboards erected on all exposed sides, except at the entrance to the hole, where a self-closing gate or an offset must be used.  On or about May 29, 2019, Wisconsin Paint and Powder Coating did not provide a self-closing gate or offset at the entrance to access platforms 1, 2 or 3 for the 5 Stage Parts Washer.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.29 B01

Serious Gravity 5 3 instances 1 exposed
Issued
Oct 29, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.29(b)(1): (1) The top edge height of top rails, or equivalent guardrail system members, are 42 inches (107 cm), plus or minus 3 inches (8 cm), above the walking-working surface.  The top edge height may exceed 45 inches (114 cm), provided the guardrail system meets all other criteria of paragraph (b) of this section (see Figure D-11).  On or about May 29, 2019 the top rail of the guardrail system for access platforms 1, 2 and 3 did not meet the minimum height requirements for providing fall protection as a guardrail system.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.29 B02

Serious Gravity 5 3 instances 1 exposed
Issued
Oct 29, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.29(b)(2): (2) Midrails, screens, mesh, intermediate vertical members, solid panels, or equivalent intermediate members are installed between the walking-working surface and the top edge of the guardrail system as follows when there is not a wall or parapet that is at least 21 inches (53 cm) high:  On or about May 29, 2019, the guardrail system for access platforms 1, 2 and 3 for the 5 Stage Parts Washer did not include a midrail or any member that would have prevented a fall through the guardrail system.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 A03

Other-than-serious 1 instance 2 exposed
Issued
Oct 29, 2019
Penalty
Initial $2,273 · Current $0 Reduced
29 CFR 1910.37(a)(3): Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level.    On or about May 29, 2019, an exit door marked #3 near the eastern spray booth was locked and bolted preventing easy egress in the event of an emergency.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2273

1910.37 B06

Other-than-serious 3 instances 5 exposed
Issued
Oct 29, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(6): Each exit sign must be illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color. Self-luminous or electroluminescent signs that have a minimum luminance surface value of at least .06 footlamberts (0.21 cd/m2) are permitted.    On or about May 29, 2019 Wisconsin Paint and Powder did not maintain illuminated Exit signs in the following areas:    a) an elevated Exit sign showing the exit route from the sandblasting and rim blaster area.    b) an elevated Exit Sign showing the exit route halfway down the southside of the parts washer.     c) an elevated Exit sign showing the exit route on the southside of the part dryer.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.106 D04 I

Deleted Serious Gravity 5 2 instances 15 exposed
Issued
Oct 29, 2019
Abate by
Nov 27, 2019
Penalty
Initial $3,789 · Current $0 Reduced
29 CFR 1910.106(d)(4)(i): "Construction." Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which drains to a safe location. Where other portions of the building or other properties are exposed, windows shall be protected as set forth in the Standard for Fire Doors and Windows, NFPA No. 80-1968, which is incorporated by reference as specified in Sec. 1910.6, for Class E or F openings. Wood at least 1 inch nominal thickness may be used for shelving, racks, dunnage, scuffboards, floor overlay, and similar installations.  On or about May 29, 2019, Wisconsin Paint and Powder Coat was using their chemical storage room for storage of flammable materials such as Acetone and Barsol A-4212. The storage room for these flammable substances did not maintain a four inch sill at the opening of the chemical room to the outer corridor or grated trench for draining fugitive flammable liquids to a safe location.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3789

1910.106 E06 II

Deleted Serious Gravity 5 2 instances 5 exposed
Issued
Oct 29, 2019
Abate by
Nov 27, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(6)(ii): Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.  On or about May 29, 2019, employees of Wisconsin Paint and Powder Coat dispensed liquid from Acetone and Barsol A-4212 drums:  a) when the grounding cables did not maintain adequate connections capable of eliminating difference in static energy potential between the drum and grounding element.  b) without bonding straps to ensure the elimination of difference in static energy between the drum and filling container.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.106 E09 III

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 29, 2019
Penalty
Initial $0 · Current $2,273
29 CFR 1910.106(e)(9)(iii): "Waste and residue." Combustible waste material and residues in a building or unit operating area shall be kept to a minimum, stored in covered metal receptacles and disposed of daily.    On or about May 29, 2019, Wisconsin Paint and Powder Coat was storing used Supertuff Paint Strainers that had been coated with flammable used paint on top of an empty paint bucket outside of the liquid spray booth.
Recent events (2)
  • — I (S) $2273.4
  • — Z (S) $0

1910.146 C01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Oct 29, 2019
Abate by
Nov 27, 2019
Penalty
Initial $3,789 · Current $0 Reduced
29 CFR 1910.146(c)(1): The employer shall evaluate the workplace to determine if any spaces are permit-required confined spaces.  NOTE: Proper application of the decision flow chart in Appendix A to section 1910.146 would facilitate compliance with this requirement.  On or about May 29, 2019, Wisconsin Paint and Powder Coat did not evaluate the facility to determine if their equipment, such as the Five Stage Part Washer or Curing Oven, met the requirements of being permit required confined spaces.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3789

1910.147 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 29, 2019
Penalty
Initial $0 · Current $2,273
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.    On or about May 29, 2019, Wisconsin Paint and Powder Coat had not developed an Energy Control Program to ensure that employees conducting maintenance or service activities are protected from the hazards of unintended re-energization.
Recent events (2)
  • — I (S) $2273.4
  • — Z (S) $0

1910.178 L04 III

Serious Gravity 1 1 instance 6 exposed
Issued
Oct 29, 2019
Penalty
Initial $2,273 · Current $1,364 Reduced
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years.    On or about May 29, 2019, Wisconsin Paint and Powder Coat had not evaluated their forklift operators every three years to ensure that the operators were capable of safely operating the forklifts.
Recent events (2)
  • — I (S) $1363.8
  • — Z (S) $2273

View Wisconsin Paint and Powder Coat's full OSHA safety record →