MACON, GA —
OSHA Inspection: DIAMOND PLASTICS CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DIAMOND PLASTICS CORPORATION in 7614 INDUSTRIAL HIGHWAY, MACON, GA 31216 (NAICS 326122). OSHA activity number 344052477.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DIAMOND PLASTICS CORPORATION
- Site address
- 7614 INDUSTRIAL HIGHWAY
- City
- MACON
- State
- GA
- ZIP
- 31216
- Mailing
- 7614 INDUSTRIAL HIGHWAY, MACON, GA 31216
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326122
- Employees
- 65
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.28 B01 I
- Issued
- Jul 2, 2019
- Abate by
- Oct 1, 2019
- Penalty
- Initial $7,577 · Current $4,550 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): Each employee on a walking/working surface having an unprotected side or edge which was four feet (1.2m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. On 6/4/19, at the Macon facility, maintenance employees were exposed to fall hazards over 7 ft. as they worked on the top of water chillers. On 5/30/19, a maintenance employee received an electrical shock while working on the top of the chiller and fell 7 ft. 3 in. to ground levels.
Recent events (2)
- — I (S) $4550
- — Z (S) $7577
1910.147 C06 I C
- Issued
- Jul 2, 2019
- Abate by
- Oct 1, 2019
- Penalty
- Initial $7,577 · Current $4,540 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected. On 6/4/19, at the Macon facility, the employer did not ensure the periodic inspection of the Lockout program included all authorized employees.
Recent events (2)
- — I (O) $4540
- — Z (S) $7577
1910.333 A02
- Issued
- Jul 2, 2019
- Abate by
- Oct 1, 2019
- Penalty
- Initial $7,577 · Current $4,550 Reduced
General-duty citation text
29 CFR 1910.333(a)(2): Where exposed live parts were not deenergized (i.e., for reasons of increased or additional hazards or infeasibility), other safety-related work practices were not used to protect employees who could be exposed to the electrical hazards involved. On 5/30/19, at the Macon facility, maintenance employees were trouble shooting fans that were not deenergized and did not use other protective measures during that work. An employee made contact with the live equipment and received an electrical shock.
Recent events (2)
- — I (S) $4550
- — Z (S) $7577
More inspections at Diamond Plastics Corporation
View Diamond Plastics Corporation's full OSHA safety record →
More inspections in this industry (NAICS 326122)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344052477.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.