ANAHEIM, CA —
OSHA Inspection: JCR CRAFTSMEN, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of JCR CRAFTSMEN, INC. in 620 S OAKWILDE DR, ANAHEIM, CA 92804 (NAICS 238390). OSHA activity number 344053582.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JCR CRAFTSMEN, INC.
- Site address
- 620 S OAKWILDE DR
- City
- ANAHEIM
- State
- CA
- ZIP
- 92804
- Mailing
- 620 S OAKWILDE DR, ANAHEIM, CA 92804
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238390
- Employees
- 4
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.107 C02
- Issued
- Nov 27, 2019
- Abate by
- Jan 2, 2020
- Penalty
- Initial $3,978 · Current $2,387 Reduced
General-duty citation text
29 CFR 1910.107(c)(2): Spark producing equipment were located in the spraying area: Pechanga Casino & Hotel; 2nd floor elevator: An employee used flammable liquids in conjunction with spark producing equipment while cleaning and refinishing the elevator with doors closed. A spraying area without spark producing equipment was not provided by the employer. The employee was exposed to smoke inhalation and contact with fire hazards.
Recent events (2)
- — I (S) $2386.8
- — Z (S) $3978
1910.107 D02
- Issued
- Nov 27, 2019
- Abate by
- Jan 2, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(d)(2): Spraying area was not provided with mechanical ventilation adequate to remove flammable vapors or mists to a safe location and to confine and control combustible residues: Pechanga Casino & Hotel; 2nd floor elevator: An employee used flammable liquids in conjunction with spark producing equipment while cleaning and refinishing the elevator with doors closed. A spraying area with adequate mechanical ventilation to remove flammable vapors or mists to a safe location was not provided by the employer. The employee was exposed to smoke inhalation and contact with fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 E03
- Issued
- Nov 27, 2019
- Abate by
- Jan 2, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(e)(3): Original closed containers, approved portable tanks, approved safety cans or a properly arranged system of piping was not used for bringing flammable liquids into spray finishing area: Pechanga Casino & Hotel; 2nd floor elevator: An employee used flammable liquids in conjunction with spark producing equipment while cleaning and refinishing the elevator with doors closed. Original closed containers, approved portable tanks, or approved safety cans for bringing flammable liquids into spray finishing area were not provided by the employer. The employee was exposed to smoke inhalation and contact with fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 D01
- Issued
- Nov 27, 2019
- Abate by
- Jan 2, 2020
- Penalty
- Initial $2,842 · Current $1,705 Reduced
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): Pechanga Casino & Hotel; 2nd floor elevator: An employee used flammable liquids while cleaning and refinishing the elevator with doors closed. The employer had not assessed the operation to determine the need for PPE. The employee was exposed to chemical contact hazards.
Recent events (2)
- — I (S) $1705.2
- — Z (S) $2842
1910.132 F01
- Issued
- Nov 27, 2019
- Abate by
- Jan 2, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(f)(1): The employer did not provide training to each employee who is required by this section to use personal protective equipment: Pechanga Casino & Hotel; 2nd floor elevator: An employee used flammable liquids while cleaning and refinishing the elevator with doors closed. The employee was not trained to know what PPE was necessary. The employee was exposed to chemical contact hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.133 A01
- Issued
- Nov 27, 2019
- Abate by
- Jan 2, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, liquid chemicals, acids or caustic liquids, chemical gases or vapors: Pechanga Casino & Hotel; 2nd floor elevator: An employee used flammable liquids while cleaning and refinishing the elevator with doors closed. The employer had not ensured that the employee used appropriate eye or face protection. The employee was exposed to chemical contact hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 C01
- Issued
- Nov 27, 2019
- Abate by
- Jan 2, 2020
- Penalty
- Initial $3,978 · Current $2,387 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: Pechanga Casino & Hotel; 2nd floor elevator: An employee used flammable liquids in conjunction with spark producing equipment while cleaning and refinishing the elevator with doors closed. A readily-available fire extinguisher was not provided by the employer. The employee was exposed to smoke inhalation and contact with fire hazards.
Recent events (2)
- — I (S) $2386.8
- — Z (S) $3978
1910.157 G02
- Issued
- Nov 27, 2019
- Abate by
- Jan 2, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: Pechanga Casino & Hotel; 2nd floor elevator: An employee used flammable liquids in conjunction with spark producing equipment while cleaning and refinishing the elevator with doors closed. Education on the general principles of fire extinguisher use upon initial assignment and annually thereafter was not provided by the employer. The employee was exposed to smoke inhalation and contact with fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at JCR Craftsmen, INC.
View JCR Craftsmen, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238390)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344053582.