OSHA Inspection: JCR CRAFTSMEN, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of JCR CRAFTSMEN, INC. in 620 S OAKWILDE DR, ANAHEIM, CA 92804 (NAICS 238390). OSHA activity number 344053582.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JCR Craftsmen, INC. — free Get an email when a new federal OSHA severe-injury report for JCR Craftsmen, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
JCR CRAFTSMEN, INC.
Site address
620 S OAKWILDE DR
City
ANAHEIM
State
CA
ZIP
92804
Mailing
620 S OAKWILDE DR, ANAHEIM, CA 92804
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238390
Employees
4
Ownership type
A

8 citations on file for this inspection.

1910.107 C02

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 27, 2019
Abate by
Jan 2, 2020
Penalty
Initial $3,978 · Current $2,387 Reduced
29 CFR 1910.107(c)(2): Spark producing equipment were located in the spraying area:    Pechanga Casino & Hotel; 2nd floor elevator: An employee used flammable liquids in conjunction with spark producing equipment while cleaning and refinishing the elevator with doors closed. A spraying area without spark producing equipment was not provided by the employer. The employee was exposed to smoke inhalation and contact with fire hazards.
Recent events (2)
  • — I (S) $2386.8
  • — Z (S) $3978

1910.107 D02

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 27, 2019
Abate by
Jan 2, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.107(d)(2): Spraying area was not provided with mechanical ventilation adequate to remove flammable vapors or mists to a safe location and to confine and control combustible residues:  Pechanga Casino & Hotel; 2nd floor elevator: An employee used flammable liquids in conjunction with spark producing equipment while cleaning and refinishing the elevator with doors closed. A spraying area with adequate mechanical ventilation to remove flammable vapors or mists to a safe location was not provided by the employer. The employee was exposed to smoke inhalation and contact with fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 E03

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 27, 2019
Abate by
Jan 2, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.107(e)(3): Original closed containers, approved portable tanks, approved safety cans or a properly arranged system of piping was not used for bringing flammable liquids into spray finishing area:  Pechanga Casino & Hotel; 2nd floor elevator: An employee used flammable liquids in conjunction with spark producing equipment while cleaning and refinishing the elevator with doors closed. Original closed containers, approved portable tanks, or approved safety cans for bringing flammable liquids into spray finishing area were not provided by the employer. The employee was exposed to smoke inhalation and contact with fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.132 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 27, 2019
Abate by
Jan 2, 2020
Penalty
Initial $2,842 · Current $1,705 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):    Pechanga Casino & Hotel; 2nd floor elevator: An employee used flammable liquids while cleaning and refinishing the elevator with doors closed. The employer had not assessed the operation to determine the need for PPE. The employee was exposed to chemical contact hazards.
Recent events (2)
  • — I (S) $1705.2
  • — Z (S) $2842

1910.132 F01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 27, 2019
Abate by
Jan 2, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.132(f)(1): The employer did not provide training to each employee who is required by this section to use personal protective equipment:  Pechanga Casino & Hotel; 2nd floor elevator: An employee used flammable liquids while cleaning and refinishing the elevator with doors closed. The employee was not trained to know what PPE was necessary. The employee was exposed to chemical contact hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.133 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 27, 2019
Abate by
Jan 2, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, liquid chemicals, acids or caustic liquids, chemical gases or vapors:  Pechanga Casino & Hotel; 2nd floor elevator: An employee used flammable liquids while cleaning and refinishing the elevator with doors closed. The employer had not ensured that the employee used appropriate eye or face protection. The employee was exposed to chemical contact hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 27, 2019
Abate by
Jan 2, 2020
Penalty
Initial $3,978 · Current $2,387 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:     Pechanga Casino & Hotel; 2nd floor elevator: An employee used flammable liquids in conjunction with spark producing equipment while cleaning and refinishing the elevator with doors closed. A readily-available fire extinguisher was not provided by the employer. The employee was exposed to smoke inhalation and contact with fire hazards.
Recent events (2)
  • — I (S) $2386.8
  • — Z (S) $3978

1910.157 G02

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 27, 2019
Abate by
Jan 2, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:  Pechanga Casino & Hotel; 2nd floor elevator: An employee used flammable liquids in conjunction with spark producing equipment while cleaning and refinishing the elevator with doors closed. Education on the general principles of fire extinguisher use upon initial assignment and annually thereafter was not provided by the employer. The employee was exposed to smoke inhalation and contact with fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View JCR Craftsmen, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344053582.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.