OSHA Inspection: LUUD INTERNATIONAL

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of LUUD INTERNATIONAL in 305 NORTH FRISCO, WINTERS, TX 79567 (NAICS 336390). OSHA activity number 344053699.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Luud International — free Get an email when a new federal OSHA severe-injury report for Luud International is published. One employer, no account, unsubscribe in one click.
Establishment
LUUD INTERNATIONAL
Site address
305 NORTH FRISCO
City
WINTERS
State
TX
ZIP
79567
Mailing
305 NORTH FRISCO, WINTERS, TX 79567
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336390
Employees
55
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 8 exposed
Issued
Sep 12, 2019
Abate by
Oct 10, 2019
Penalty
Initial $9,282 · Current $5,569 Reduced
Section 5(a)(l) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by hazards:   On or about June 03, 2019, and at times prior thereto, at a workplace located at 305 North Frisco Street, Winters, Texas; employees operate a Hydraulic Jack, by pendant control, to handle suspended loads (truck utility boxes/toolboxes).
Recent events (2)
  • — I (S) $5569.2
  • — Z (S) $9282

1910.134 E01

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 12, 2019
Abate by
Oct 10, 2019
Penalty
Initial $9,282 · Current $5,569 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:     On or about June 03, 2019, and at times prior thereto, at a workplace located at 305 North Frisco Street, Winters, Texas; the employer did not provide medical evaluation to employees before the employee was required to use the respirator in the workplace.
Recent events (2)
  • — I (S) $5569.2
  • — Z (S) $9282

1910.134 F02

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 12, 2019
Abate by
Oct 10, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): The employer did not ensure that an employee using a tight-fitting facepiece respirators is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter:     On or about June 03, 2019, and at times prior thereto, at a workplace located at 305 North Frisco Street, Winters, Texas; employees required to use respirators were not fit tested prior to respirator use and annually.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 E01 II

Serious Gravity 5 1 instance 21 exposed
Issued
Sep 12, 2019
Abate by
Oct 10, 2019
Penalty
Initial $6,630 · Current $3,978 Reduced
29 CFR 1910. 303(e)(1)(ii): Markings were not provided for voltage, current, wattage, and other ratings as necessary:    On or about June 03, 2019, and at times prior thereto, at a workplace located at 305 North Frisco Street, Winters, Texas; the employer had electrical panel boxes that were energized with no marked voltage ratings.
Recent events (2)
  • — I (S) $3978
  • — Z (S) $6630

1910.1200 E01

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 12, 2019
Abate by
Oct 10, 2019
Penalty
Initial $3,978 · Current $2,387 Reduced
CFR 1910. 1200(e)(1): Employer did not develop, implement, and maintain at each work place, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning:        On or about June 03, 2019, and at times prior thereto, at a workplace located at 305 North Frisco Street, Winters, Texas; the employer did not ensure that a written hazard communication program with all the required elements was available at the workplace for employees using chemicals such as Barium Sulfate, Acetone, Methanol and Benzene.
Recent events (2)
  • — I (S) $2386.8
  • — Z (S) $3978

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344053699.