OSHA Inspection: BRYANT BROTHER'S WELDING AND STEEL ERECTION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BRYANT BROTHER'S WELDING AND STEEL ERECTION in BUILDING 2004 BARNETT AVE. MCB MINI MART QUANTICO AT HOT PATCH RD., QUANTICO, VA 22134 (NAICS 238120). OSHA activity number 344056940.

Watch Bryant Brother'S Welding AND Steel Erection — free Get an email when a new federal OSHA severe-injury report for Bryant Brother'S Welding AND Steel Erection is published. One employer, no account, unsubscribe in one click.
Site address
BUILDING 2004 BARNETT AVE. MCB MINI MART QUANTICO AT HOT PATCH RD.
City
QUANTICO
State
VA
ZIP
22134
Mailing
11100 CATHARPIN RD., SPOTSYLVANIA, VA 22553
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.351 B02

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3978.00 · Current $2586.00 Reduced
29 CFR 1926.351(b)(2): Welding cable(s) in use were not free from improper repair or splices for a minimum distance of 10 feet from the cable end to which the electrode holder was connected:  (a) On or about 06-04-2019 and times prior thereto, Bryant Brothers Welding and Steel Erection, located at U.S.M.C. Base Quantico (Future Site of Quantico Marine Mart), Building 27406 at MCBI St. & Hot Patch Rd. Quantico, VA 27406:  An employee was exposed to electrical hazards from a defective welding cable with many improper repairs made within 10 feet of the electrode holder.  A slice located at 13 inches and 60 inches from the electrode holder, with exposed copper conductors, was found with wrapped electrical tape covering it.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $2585.7
  • — Z (S) $3978

1926.760 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3978.00 · Current $2586.00 Reduced
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems.  (a) On or about 06-04-2019 and times prior thereto, Bryant Brothers Welding and Steel Erection, located at U.S.M.C. Base Quantico (Future Site of Quantico Marine Mart), Building 27406 at MCBI St. & Hot Patch Rd. Quantico, VA 27406:  Employee(s) were exposed to unprotected falls in excess of 17 feet, 6 inches while attaching metal roofing panels on top of the steel erected structure.   Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $2585.7
  • — Z (S) $3978

1926.761 B

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3978.00 · Current $2586.00 Reduced
29 CFR 1926.761(b): The employer did not train each employee exposed to a fall hazard in accordance with the requirements of 29 CFR 1926.761:  (a) On or about 06-04-2019 and times prior thereto, Bryant Brothers Welding and Steel Erection, located at U.S.M.C. Base Quantico (Future Site of Quantico Marine Mart), Building 27406 at MCBI St. & Hot Patch Rd. Quantico, VA 27406:  Employee(s) were not trained to hazards that exposed them to unprotected falls in excess of 17 feet, 6 inches while attaching metal roofing panels on top of the steel erected structure.   Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $2585.7
  • — Z (S) $3978

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344056940.