Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FEL GLO INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FEL GLO INC. in 2250 ANGLERS PLACE RD, BROWNSVILLE, TX 78521 (NAICS 332710). OSHA activity number 344060389.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch FEL GLO INC. — free Get an email when a new federal OSHA severe-injury report for FEL GLO INC. is published. One employer, no account, unsubscribe in one click.
Establishment
FEL GLO INC.
Site address
2250 ANGLERS PLACE RD
City
BROWNSVILLE
State
TX
ZIP
78521
Mailing
2250 ANGLERS PLACE RD, BROWNSVILLE, TX 78521
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
18
Ownership type
A

6 citations on file for this inspection.

1910.178 F02

Serious Gravity 5 2 instances 2 exposed
Issued
Dec 2, 2019
Abate by
Dec 27, 2019
Penalty
Initial $3,220 · Current $1,932 Reduced
29 CFR 1910.178(f)(2): 29 CFR 1910.178(f)(2):  The storage and handling of liquefied petroleum gas fuel was not in accordance with NFPA No. 58-1969, Storage and Handling of Liquefied Petroleum Gases. Section 6.21.3.4(B): Fuel containers shall be mounted to prevent jarring loose and slipping or rotating, and the fastening shall be designed and constructed to withstand, without permanent visible deformation, static loading in any direction equal to four times the weight of the container filled with fuel:  Employer did not ensure power industrial trucks running on liquefied petroleum gas fasteners were used to secure gas container on to forklifts such as but not limited to:   a. 50 Nissan b. 90 Nissan
Recent events (2)
  • — I (S) $1932
  • — Z (S) $3220

1910.178 L01

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 2, 2019
Abate by
Dec 27, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(1): The employer did not ensure that each power industrial truck operator was competent to operate a power industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in paragraph (1):  Employees operated a forklift in this metal fabrication shop were not trained and evaluated in power industrial truck operation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 Q01

Serious Gravity 5 5 instances 2 exposed
Issued
Dec 2, 2019
Abate by
Dec 27, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel:  Power industrial trucks operated by employees are not in safe operating conditions such as but not limited to:  a. 90 Nissan: missing seat belt, clips missing off gas cylinder, inspection b. 50 Nissan: missing seat, seat belt, clips missing off gas cylinder, inspection c. CP 60: missing seat, seat belt and clips missing gas cylinder, inspection
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B02 II

Serious Gravity 5 2 instances 2 exposed
Issued
Dec 2, 2019
Abate by
Dec 27, 2019
Penalty
Initial $2,576 · Current $1,546 Reduced
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior:   In the welding shop area cylinders were not secure or stored in a well-protected location such as but not limited to:  a. Nitrogen cylinder in the welding shop area b. Oxygen cylinder in the welding shop area
Recent events (2)
  • — I (S) $1545.6
  • — Z (S) $2576

1910.303 B07 IV

Serious Gravity 5 3 instances 2 exposed
Issued
Dec 2, 2019
Abate by
Dec 27, 2019
Penalty
Initial $3,220 · Current $1,932 Reduced
29 CFR 1910.303(b)(7)(iv): There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating:  Electrical breaker panels throughout the facility were corroded and in need of repair such as but not limited to:   a. Main breaker box b. Breaker box in machine shop are.  c. Break box in shop area.
Recent events (2)
  • — I (S) $1932
  • — Z (S) $3220

1910.303 F02

Serious Gravity 5 5 instances 2 exposed
Issued
Dec 2, 2019
Abate by
Dec 27, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  Employees working on metal fabrication exposed to electrical hazards such as but not limited to missing labels on panels and circuit feeders:  a. Electrical panel in machine shop area south side   b. Electrical panel in main entrance, main panel  c. Electrical panel in main entrance
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344060389.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.