GROVER, CO —
OSHA Inspection: ARCHROCK SERVICES L.P.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of ARCHROCK SERVICES L.P. in 67509 WELD COUNTY ROAD 71, GROVER, CO 80729 (NAICS 213112). OSHA activity number 344060728.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARCHROCK SERVICES L.P.
- Site address
- 67509 WELD COUNTY ROAD 71
- City
- GROVER
- State
- CO
- ZIP
- 80729
- Mailing
- 9807 KATY FREEWAY SUITE 100, HOUSTON, TX 77024
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.1200 H03 I
- Issued
- Nov 18, 2019
- Abate by
- Dec 23, 2019
- Penalty
- Initial $6,440 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1200(h)(3)(i): The employer did not ensure that employee training included methods and observations that may be used to detect the presence or release of a hazardous chemical in the work area (such as monitoring conducted by the employer, continuous monitoring devices, visual appearance or odor of hazardous chemicals when being released, etc.): a) Archrock Services L.P. at 67509 Weld County Road 71 in Grover, CO 80729: On or before 06/05/19, the employer did not ensure that employee training included methods and observations that may be used to detect the presence or release of a hazardous chemical in the work area (such as monitoring conducted by the employer, continuous monitoring devices, visual appearance or odor of hazardous chemicals when being released, etc.). The employer directed the work of a subcontractor. The work involved opening process equipment which potentially contained hydrocarbon gases, including natural gas liquids. The release of hydrocarbon gases triggered Lower Explosive Limit (LEL) alarms on the employee's 4 gas meter. The employee and subcontractor employees continued to work until a flash fire occurred. The employer did not provide effective training in that the employee failed to recognize and to respond appropriately to the LEL alarms of the 4 gas meter. This condition exposed the employee and employees of the subcontractor to fire and explosion hazards.
Recent events (3)
- — F (S) $0
- — C (S) $6440
- — Z (S) $6440
1910.1200 H03 III
- Issued
- Nov 18, 2019
- Abate by
- Dec 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(3)(iii): Employee training did not include the measures employees can take to protect themselves from chemical hazards, including specific procedures the employer had implemented to protect employees from exposure to hazardous chemicals, such as appropriate work practices, emergency procedures and personal protective equipment to be used: a) Archrock Services L.P. at 67509 Weld County Road 71 in Grover, CO 80729: On or before 06/05/19, the employer did not ensure that employee training included the measures employees can take to protect themselves from chemical hazards, including specific procedures the employer had implemented to protect employees from exposure to hazardous chemicals, such as appropriate work practices, emergency procedures and personal protective equipment to be used. The employer directed the work of a subcontractor. The work involved opening process equipment which potentially contained hydrocarbon gases, including natural gas liquids. The release of hydrocarbon gases triggered Lower Explosive Limit (LEL) alarms on the employee's 4 gas meter. The employee and subcontractor employees continued to work until a flash fire occurred. The employer did not provide effective training, in that the employee did not recognize that using a non-intrinsically safe impact wrench in the presence of LEL alarms, signifying the presence of flammable gases, acted as an ignition source for a fire or explosion. This condition exposed the employee and employees of the subcontractor to fire and explosion hazards.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at Archrock Services L.P.
View Archrock Services L.P.'s full OSHA safety record →
More inspections in this industry (NAICS 213112)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344060728.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.