Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: QUALITY EXTERIOR AND REMODELING LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of QUALITY EXTERIOR AND REMODELING LLC in 1905 CRALEY ROAD, WINDSOR, PA 17366 (NAICS 238160). OSHA activity number 344062468.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quality Exterior and Remodeling LLC — free Get an email when a new federal OSHA severe-injury report for Quality Exterior and Remodeling LLC is published. One employer, no account, unsubscribe in one click.
Site address
1905 CRALEY ROAD
City
WINDSOR
State
PA
ZIP
17366
Mailing
33 LOCUST GROVE ROAD, YORK, PA 17402
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

3 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Nov 15, 2019
Abate by
Dec 20, 2019
Penalty
Initial $319 · Current $319
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  (a) 1905 Craley Road, Windsor Pennsylvania - The employer did not certify that the citations had been abated within 10 days of the abatement date, on or about November 5, 2019.      Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • — Z (O) $319

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 25, 2019
Abate by
Oct 22, 2019
Penalty
Initial $3,126 · Current $3,126
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  (a) Porch Roof - To gain access to the porch roof, employees used a portable extension ladder, positioned at the front of the house.  The ladder only extended two feet above the porch roof (upper landing) surface, exposing the employees to the hazard of falling 8.5 feet to the ground below, on or about June 6, 2019.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $3126

1926.501 B13

Repeat Gravity 5 1 instance 3 exposed
Issued
Sep 25, 2019
Abate by
Oct 22, 2019
Penalty
Initial $15,629 · Current $15,629
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor were employees provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):  (a) Porch Roof - Employees tore off the porch roof, and the employees did not use any fall protection, exposing the employees to the hazard of falling 8.5 feet from the roof to the ground below at the front of the house and 19 feet from the roof to the ground below at the rear of the house, on or about June 6, 2019.  Quality Exterior and Remodeling, LLC was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1926.501(b)(13), which was contained in:  OSHA inspection number 1339960, citation number 1, item number 1 and was affirmed as a final order on May 31, 2019, with respect to a workplace located at 1001 N. 17th Street, Harrisburg, Pennsylvania  17105; and  OSHA inspection number 1319754, citation number 1, item number 1 and was affirmed as a final order on August 13, 2018, with respect to a workplace located at 77 Grant Street, Manheim, Pennsylvania  17545.  Abatement certification and documentation is required within 10 days after the abatement date.  The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • — Z (R) $15629

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344062468.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.