Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RAINBOW MANUFACTURING, INC. DBA RAINBOW GRAPHICS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RAINBOW MANUFACTURING, INC. DBA RAINBOW GRAPHICS in 933 TOWER ROAD, MUNDELEIN, IL 60060 (NAICS 323119). OSHA activity number 344069935.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rainbow Manufacturing, INC. DBA Rainbow Graphics — free Get an email when a new federal OSHA severe-injury report for Rainbow Manufacturing, INC. DBA Rainbow Graphics is published. One employer, no account, unsubscribe in one click.
Site address
933 TOWER ROAD
City
MUNDELEIN
State
IL
ZIP
60060
Mailing
933 TOWER ROAD, MUNDELEIN, IL 60060
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323119
Employees
42
Ownership type
A

7 citations on file for this inspection.

1910.147 D

Serious Gravity 10 1 instance 10 exposed
Issued
Nov 12, 2019
Abate by
Jan 10, 2020
Penalty
Initial $9,282 · Current $6,800 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) was not done in sequence to achieve energy control by performing the following steps as required by 29 CFR 1910.147(d)(1)-(6):  1.     Turn off and shut down power to the machinery,  2.     Physically locate and operate energy-isolating devices in such a manner as to isolate the machine or equipment from the energy source(s),  3.     Affix lockout/tagout devices to each energy isolating device,   4.     Verify isolation and de-energization of machinery have been accomplished prior to starting the maintenance and/or servicing work:      a) Production Department- On or about June 26, 2019, employees were exposed to machine hazards associated with moving parts while performing maintenance and servicing tasks on the printing presses, including replacing  rollers and cleaning ink off rollers. The employer did not implement energy control application steps as the machine was not shut down or turned off to clean or remove rollers or ensuring that the inch mode button is not held down during the roller cleaning process [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving dissipation machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
  • — I (S) $6800
  • — Z (S) $9282

1910.333 B02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 12, 2019
Abate by
Jan 10, 2020
Penalty
Initial $3,978 · Current $0 Reduced
29 CFR 1910.333(b)(2)(i): The employer did not maintain a written copy of the procedures outlined in paragraph (b)(2) of 29 CFR 1910.333 and did not make it available for inspection by employees and the Assistant Secretary of Labor and his or her authorized representatives:      a) Facility wide- On or about May 15, 2019, the employer did not maintain a copy of the written safety related work practice procedures outlined in 29 CFR 1910.333(b)(2) for employees working on or near exposed energized parts and did not make it available to employees or authorized representatives during the inspection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3978

1910.335 A01 I

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 12, 2019
Abate by
Dec 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:     a) Facility wide- On or about May 15, 2019, the employer did not ensure that electrical protective equipment was provided for employees performing troubleshooting tasks on or near exposed energized parts, such as electrical rated rubber gloves with leather over gloves to protect from electrical shock hazards.       In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L04 III

Other-than-serious 1 instance 1 exposed
Issued
Nov 12, 2019
Abate by
Dec 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:    a) Production Department/Shipping and Receiving- On or about June 6, 2019, the employer did not ensure that an evaluation of the operator's knowledge and skill to operate the power industrial vehicles safely was performed every three years for each type of vehicle operated.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.179 G01 V

Other-than-serious 1 instance 10 exposed
Issued
Nov 12, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.179(g)(1)(v): Pendant control boxes shall be constructed to prevent electrical shock and shall be clearly marked for identification of functions:    a) Production Department- On June 6, 2019, the employer did not ensure that the pendant control boxes for the cranes on the two Martin Automatic A52, Didde VIP, and Didde 860 Printing Press lines were clearly marked to identify the functions of the control buttons.   No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.179 J02

Other-than-serious 1 instance 10 exposed
Issued
Nov 12, 2019
Abate by
Dec 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.179(j)(2): Overhead cranes were not inspected for defects on a daily basis for items including but not limited to; all functional operating mechanisms for maladjustment, deterioration or leakage of air or hydraulic systems and hooks:  a) Production Department- On or about June 6, 2019, the employer did not ensure that daily inspections of the hoisting equipment was conducted to identify any defects.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.179 J03

Other-than-serious 1 instance 10 exposed
Issued
Nov 12, 2019
Abate by
Dec 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.179(j)(3): A complete periodic inspection of crane(s) had not been conducted in the past 12 months or in intervals as generally defined in paragraph (j)(1)(ii)(b) of this section:    a) Production Department- On or about June 6, 2019, the employer did not ensure that a complete inspection of the hoisting equipment is conducted once per year.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344069935.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.