HORSEHEADS, NY —
OSHA Inspection: SOUTHERN TIER LOGISTICS, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of SOUTHERN TIER LOGISTICS, INC. in 50 ELECTRIC PARKWAY, HORSEHEADS, NY 14845 (NAICS 493110). OSHA activity number 344074364.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOUTHERN TIER LOGISTICS, INC.
- Site address
- 50 ELECTRIC PARKWAY
- City
- HORSEHEADS
- State
- NY
- ZIP
- 14845
- Mailing
- 50 ELECTRIC PARKWAY, HORSEHEADS, NY 14845
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 105
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.95 C01
- Issued
- Jun 28, 2019
- Abate by
- Aug 2, 2019
- Penalty
- Initial $10,229 · Current $6,137 Reduced
81108111
General-duty citation text
29 CFR 1910.95(c)(1): A continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (n) was not instituted when employee noise exposures equaled or exceeded an 8 hour time-weighted average sound level (TWA) of 85 dBA: a) Pack Reclamation Area, on or about 6/18/19: A Pack Reclamation Operator was cleaning plastic trays off with compressed air and was exposed to continuous noise at a level of 221% of the dose of the OSHA permissible exposure limit. The equivalent dBA for the 221% dose is approximately 92.7 dBA calculated as the 8 hour time weighted sound pressure level. The sampling was conducted on 6/18/19 for 441 minutes. Exposure calculations include a zero increment for the 39 minutes not sampled. Employee was wearing ear plugs. Employer does not have hearing conservation program implemented. b) Wash Department, on or about 6/18/19: A Laborer working in the Wash Room was exposed to continuous noise at a level of 114.7% of the dose of the OSHA permissible exposure limit. The equivalent dBA for the 114.7% dose is approximately 91.4 dBA calculated as the 8 hour time weighted sound pressure level. The sampling was conducted on 6/18/19 for 437 minutes. Exposure calculations include a zero increment for the 43 minutes not sampled. Employee was wearing ear plugs. Employer does not have hearing conservation program implemented. c) Wash Department, on or about 6/18/19: A Laborer working in the Wash Room was exposed to continuous noise at a level of 120.0% of the dose of the OSHA permissible exposure limit. The equivalent dBA for the 120.0% dose is approximately 91.5 dBA calculated as the 8 hour time weighted sound pressure level. The sampling was conducted on 6/18/19 for 432 minutes. Exposure calculations include a zero increment for the 48 minutes not sampled. Employee was wearing ear plugs. Employer does not have hearing conservation program implemented. Abatement methodology: Step 1: An effective hearing conservation program in accordance with 29 CFR 1910.95(c) through (n) shall be maintained. An effective hearing conservation program shall include, at a minimum: (1) A baseline audiogram for all employees exposed to noise levels equal to or in excess of the standard. (2) Annual audiograms for each overexposed employee. (3) analysis of audiogram results with retesting and/or referral to an otolaryngologist or qualified physician when a significant threshold shift occurs. A significant shift will be considered to be equal to or greater than an average of 30 dba over the 2000, 3000, and 4000 hertz frequencies. (4) Where insert ear plugs or custom-molded devices are utilized, individual employee fitting shall be conducted by a trained person, and employees shall be instructed in the care and use of the devices.
Recent events (2)
- — I (S) $6137.4
- — Z (S) $10229
1910.95 I02 I
- Issued
- Jun 28, 2019
- Penalty
- Initial $0 · Current $0
8110
General-duty citation text
29 CFR 1910.95(i)(2)(i): The wearing of hearing protectors was not ensured for employees exposed to sound levels exceeding those listed in Table G16 of 29 CFR 1910.95 as required by 29 CFR 1910.95(b)(1): a) Pack Reclamation Area, on or about 6/18/19: A Pack Reclamation Operator was cleaning plastic trays off with compressed air and was exposed to continuous noise at a level of 221% of the dose of the OSHA permissible exposure limit. The equivalent dBA for the 221% dose is approximately 92.7 dBA calculated as the 8 hour time weighted sound pressure level. The sampling was conducted on 6/18/19 for 441 minutes. Exposure calculations include a zero increment for the 39 minutes not sampled. Employee was wearing ear plugs on 6/18/19 however, employee was observed not wearing hearing protection on 5/14/19.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Southern Tier Logistics, INC.
View Southern Tier Logistics, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 493110)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344074364.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.