Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: D COMMERCIAL REFRIGERATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of D COMMERCIAL REFRIGERATION in 3625 LAWNWOOD ST., FORT WORTH, TX 76111 (NAICS 811412). OSHA activity number 344078068.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch D Commercial Refrigeration — free Get an email when a new federal OSHA severe-injury report for D Commercial Refrigeration is published. One employer, no account, unsubscribe in one click.
Site address
3625 LAWNWOOD ST.
City
FORT WORTH
State
TX
ZIP
76111
Mailing
3625 LAWNWOOD ST., FORT WORTH, TX 76111
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811412
Employees
25
Ownership type
A

5 citations on file for this inspection.

1910.37 B02

Serious Gravity 1 2 instances 25 exposed
Issued
Jun 14, 2019
Abate by
Jul 15, 2019
Penalty
Initial $2,273 · Current $1,364 Reduced
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit".   At the facility, the employer did not ensure exit doors were equipped or identified with an "EXIT" sign exposing employees to entrapment hazards at locations;  a.  Front entrance no "EXIT" sign,  b.  Fabrication building entrance door no "EXIT" sign.
Recent events (2)
  • — I (S) $1363.8
  • — Z (S) $2273

1910.253 B02 II

Serious Gravity 5 2 instances 25 exposed
Issued
Jun 14, 2019
Penalty
Initial $2,576 · Current $1,546 Reduced
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders were not located where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:   At the facility, the employer did not ensure compressed gas cylinders were secured exposing employees to struck-by hazards at locations;  a.  Shop area, several cylinders were not secured,  b.  Fabrication building cylinders were not secured.
Recent events (2)
  • — I (S) $1545.6
  • — Z (S) $2576

1910.253 B02 IV

Serious Gravity 1 2 instances 25 exposed
Issued
Jun 14, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use.     At the facility, the employer did not ensure compress gas cylinders were stored with the protective caps installed on the cylinder head exposing employees to struck-by hazards at locations;  a.  Shop area, cylinders stored without protective caps,  b.  Fabrication building cylinders stored without protective caps.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 5 2 instances 25 exposed
Issued
Jun 14, 2019
Penalty
Initial $3,864 · Current $2,318 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy.     In the shop area, employees used a 4 way electrical box as a switch and to power equipment without a cover plate exposing employees to electrical shock hazards.
Recent events (2)
  • — I (S) $2318.4
  • — Z (S) $3864

1910.303 E01 II

Other-than-serious 2 instances 25 exposed
Issued
Jun 14, 2019
Penalty
Initial $361 · Current $217 Reduced
29 CFR 1910.303(e)(1)(ii): Electric equipment was used without markings giving voltage, current, wattage, or other ratings as necessary:   In the shop area, the employer did not ensure electrical panels were marked with voltage, current or wattage rating exposing employees to electrical shock hazards.
Recent events (2)
  • — I (O) $216.6
  • — Z (O) $361

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344078068.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.