Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: C.N. WOOD COMPANY INCORPORATED

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of C.N. WOOD COMPANY INCORPORATED in 200 MERRIMAC STREET, WOBURN, MA 01801 (NAICS 333120). OSHA activity number 344089271.

Watch C.N. Wood Company Incorporated — free Get an email when a new federal OSHA severe-injury report for C.N. Wood Company Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
200 MERRIMAC STREET
City
WOBURN
State
MA
ZIP
01801
Mailing
200 MERRIMAC STREET, WOBURN, MA 01801
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333120
Employees
115
Ownership type
A

6 citations on file for this inspection.

1910.134 D01 III

Serious Gravity 1 2 instances 26 exposed
Issued
Abate by
Penalty
Initial $5115.00 · Current $2046.00 Reduced
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:    200 Merrimac Street, Woburn, MA 01801, Environmental and Construction Shop    a) On or about 6/18/19, an assessment of respiratory hazards was not performed for employees voluntarily wearing tight fitting half face respirators.
Recent events (2)
  • — I (S) $2046
  • — Z (S) $5115

1910.134 E01

Serious Gravity 1 2 instances 26 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  200 Merrimac Street, Woburn, MA 01801, Environmental and Construction Shop  a) On or about 6/18/19, employees voluntarily wearing tight fitting half face respirators were not medically evaluated prior to using the respirator.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 I

Serious Gravity 5 1 instance 26 exposed
Issued
Abate by
Penalty
Initial $8525.00 · Current $3410.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    200 Merrimac Street, Woburn, MA 01801, Environmental and Construction Shop    a) On or about 6/18/19, employees engaged in the repair of heavy equipment did not use procedures to ensure that equipment that included hydraulic controls were locked out to prevent the unanticipated release of energy.
Recent events (3)
  • — P (S) $3410
  • — I (S) $3410
  • — Z (S) $8525

1910.253 B04 III

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $8525.00 · Current $3410.00 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour:    200 Merrimac Street, Woburn, MA 01801, Outside construction shop.    a) On or about 6/18/19, employees  were exposed to burn injuries from oxygen and acetylene gas that were stored adjacent to one another.
Recent events (2)
  • — I (S) $3410
  • — Z (S) $8525

1910.37 A01

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(a)(1): Exit routes must be kept free of explosive or highly flammable furnishings or other decorations.  200 Merrimac Street, Woburn, MA 01801, Outside construction shop.  a) On or about 6/18/19, employees  were exposed to burn injuries from oxygen and acetylene gas that were stored adjacent to one another. Employees evacuating in the event of an emergency may pass by these cylinders when exiting the facility.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01

Serious Gravity 5 1 instance 10 exposed
Issued
Penalty
Initial $10229.00 · Current $4092.00 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    200 Merrimac Street, Woburn, MA 01801. Parts department.     a) On or about 6/18/19, employees were exposed to shock and fire hazards due to cardboard that was blocking access to electrical equipment.
Recent events (2)
  • — I (S) $4091.6
  • — Z (S) $10229