SPRINGFIELD, OH —
OSHA Inspection: NAVISTAR, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NAVISTAR, INC. in 6125 URBANA ROAD, SPRINGFIELD, OH 45502 (NAICS 336211). OSHA activity number 344090535.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NAVISTAR, INC.
- Site address
- 6125 URBANA ROAD
- City
- SPRINGFIELD
- State
- OH
- ZIP
- 45502
- Mailing
- 6125 URBANA ROAD, SPRINGFIELD, OH 45502
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336211
- Employees
- 250
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.333 A02
- Issued
- Oct 8, 2019
- Penalty
- Initial $13,260 · Current $6,630 Reduced
General-duty citation text
29 CFR 1910.333(a)(2): "Energized parts." If the exposed live parts are not deenergized (i.e., for reasons of increased or additional hazards or infeasibility), other safety-related work practices shall be used to protect employees who may be exposed to the electrical hazards involved. Such work practices shall protect employees against contact with energized circuit parts directly with any part of their body or indirectly through some other conductive object. The work practices that are used shall be suitable for the conditions under which the work is to be performed and for the voltage level of the exposed electric conductors or circuit parts. Specific work practice requirements are detailed in paragraph (c) of this section. a) On June 18, 2019, in Department 51, Location 517, employees in this location while the hoist system was being worked on were not removed and protected from exposure to electrical hazards from the energized 460v hoist equipment when they touched the suspended load and received an electrical shock.
Recent events (2)
- — I (S) $6630
- — Z (S) $13260
More inspections at Navistar, INC.