OSHA Inspection: ARMY AIR FORCE EXCHANGE SERVICE 8DDEX0061

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ARMY AIR FORCE EXCHANGE SERVICE 8DDEX0061 in 53228 DEBRY ST. BLDG 352 MCCONNELL AFB, WICHITA, KS 67221 (NAICS 453998). OSHA activity number 344092564.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Army AIR Force Exchange Service 8ddex0061 — free Get an email when a new federal OSHA severe-injury report for Army AIR Force Exchange Service 8ddex0061 is published. One employer, no account, unsubscribe in one click.
Site address
53228 DEBRY ST. BLDG 352 MCCONNELL AFB
City
WICHITA
State
KS
ZIP
67221
Mailing
53228 DEBRY ST. BLDG 352 MCCONNELL AFB, WICHITA, KS 67221
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
453998
Employees
18
Ownership type
D

3 citations on file for this inspection.

1910.36 G02

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 23, 2019
Abate by
Sep 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points.  The employees were exposed to a lack of safe means of egress in the event of an emergency. In the storage warehouse, workers unboxing and hanging apparel did not have the required 28 inches wide exit path that would allow access to an exit door. One of the means of egress was restricted to only 20 inches wide and the only other possible exit path was blocked with boxes.
Recent events (1)
  • — Z (S) $0

1910.37 B02

Serious Gravity 5 1 instance 16 exposed
Issued
Aug 23, 2019
Abate by
Sep 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  The employees were exposed to injury in the event of an emergency. The employees working in the exchange service facility were in danger of being trapped in an emergency situation. In the outdoor fenced area, an exit door was not marked with any signage to indicate its use as an exit.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 23, 2019
Abate by
Sep 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   The employees were exposed to caught-in hazards. The employees working in the storage warehouse operating the conveyor belt were exposed to ingoing nip points. The end of the conveyor belt had nip points located on both sides where the belt wrapped around the rollers and was not guarded.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344092564.