LAREDO, TX —
OSHA Inspection: C.V.R. LATH & PLASTERING, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of C.V.R. LATH & PLASTERING, LLC in 7110 ROCIO DR, LAREDO, TX 78040 (NAICS 238140). OSHA activity number 344095369.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- C.V.R. LATH & PLASTERING, LLC
- Site address
- 7110 ROCIO DR
- City
- LAREDO
- State
- TX
- ZIP
- 78040
- Mailing
- 6302 ALOE VERA DR, LAREDO, TX 78043
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 12
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.100 A
- Issued
- Jun 26, 2019
- Penalty
- Initial $3,789 · Current $3,789
General-duty citation text
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: Employees worked on a lower scaffold platform and on the ground below other workers conducting lath & plastering activities and were not wearing hardhats.
Recent events (1)
- — Z (S) $3789
1926.451 B01
- Issued
- Jun 26, 2019
- Penalty
- Initial $5,304 · Current $5,304
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) Employees conducted lath and plastering activities from a two-tiered frame scaffold system that was not fully planked on both levels.
Recent events (1)
- — Z (S) $5304
1926.451 C02
- Issued
- Jun 26, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: Employees conducted lath and plastering activities from a two-tiered frame scaffold system that did not have mud sills under the base plates on the dirt foundation.
Recent events (1)
- — Z (S) $0
1926.451 E01
- Issued
- Jun 26, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. Employees conducted lath and plastering activities from a two-tiered frame scaffold system and climbed the frame of the scaffold to access the working levels.
Recent events (1)
- — Z (S) $0
1926.451 F03
- Issued
- Jun 26, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: Employees conducted lath and plastering activities from a two-tiered frame scaffold system with several deficiencies such as no ladder, no guardrails, no mudsills and not fully planked on working levels.
Recent events (1)
- — Z (S) $0
1926.451 G01
- Issued
- Jun 26, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. Employees conducted lath and plastering activities from a two-tiered frame scaffold system that did not have guardrails on either level.
Recent events (1)
- — Z (S) $0
More inspections at C.V.R. Lath & Plastering, LLC
View C.V.R. Lath & Plastering, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in TX
Source