WINSTED, CT —
OSHA Inspection: ELECTRIC MOTION COMPANY, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ELECTRIC MOTION COMPANY, INC. in 157 COLEBROOK RIVER ROAD, WINSTED, CT 06098 (NAICS 335931). OSHA activity number 344097688.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ELECTRIC MOTION COMPANY, INC.
- Site address
- 157 COLEBROOK RIVER ROAD
- City
- WINSTED
- State
- CT
- ZIP
- 06098
- Mailing
- 157 COLEBROOK RIVER ROAD, WINSTED, CT 06098
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335931
- Employees
- 140
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.147 C04 I
- Issued
- Aug 29, 2019
- Penalty
- Initial $7,246 · Current $3,623 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On, or about, June 17, 2019, the following mechanical power presses were not locked out when tool punches/inserts were changed. The stations were not protected by safeguarding such as a light curtain, when employees accessed the tooling: A. Press 50, Bliss partial revolution press, station accessed through hinged plexiglass door at back of press. B. Press 332, a V&O partial revolution press, station accessed through the side of the guard. C. Press 334, a Walsh partial revolution press, station accessed through the side of the guard.
Recent events (2)
- — I (S) $3623
- — Z (S) $7246
1910.217 D09 IV
- Issued
- Aug 29, 2019
- Abate by
- Oct 17, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(d)(9)(iv): Safety blocks were not used when mechanical power press die(s) were being adjusted or repaired in the press: On, or about, June 17, 2019, die blocks were not used when tool punches/inserts were changed in the following mechanical power presses: A. Press 50, Bliss partial revolution press. B. Press 332, V&O partial revolution press. C. Press 334, Walsh partial revolution press.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.169 A02 I
- Issued
- Aug 29, 2019
- Abate by
- Oct 17, 2019
- Penalty
- Initial $4,347 · Current $0 Reduced
General-duty citation text
29 CFR 1910.169(a)(2)(i): Air receivers were not constructed in accordance with the 1968 edition of the A.S.M.E. Boiler and Pressure Vessel Code, Section VIII, which is incorporated by reference as specified in 1910.6: Press Room, Deep Draw: On, or about, June 17, 2019, air tanks provided at the following Bliss eyelet presses were not constructed in accordance with ASME standards: A. Press 60. B. Press 61. C. Press 62.
Recent events (2)
- — I (S) $0
- — Z (S) $4347
1910.169 B03 I
- Issued
- Aug 29, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.169(b)(3)(i): Compressed air receiver(s) were not equipped with one or more spring-loaded safety valves: Press Room, Deep Draw: On, or about, June 17, 2019, air tanks provided at the following Bliss eyelet presses were not equipped with pressure relief valves: A. Press 77. B. Press 60. C. Press 61. D. Press 62.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.217 B12
- Issued
- Aug 29, 2019
- Abate by
- Oct 17, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(b)(12): All pressure vessels used in conjunction with power presses did not conform to the American Society of Mechanical Engineers Code for Pressure Vessels, 1968 Edition: Ref. 1968 ASME BPVC, Section UG-125. Press Room: On, or about, June 17, 2019, pressure relief valves were not provided on air tanks mounted on the following mechanical power presses: A. Press 332, V&O. B. Press 364, Havir.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.217 C03 III F
- Issued
- Aug 29, 2019
- Penalty
- Initial $3,695 · Current $1,848 Reduced
General-duty citation text
29 CFR 1910.217(c)(3)(iii)(f): Mechanical power press(es) using presence sensing point of operation devices were not provided with guards to protect all areas of entry to the point of operation not protected by the presence sensing device(s): Press Room: On, or about, June 17, 2019, the die area of the press was accessible through a gap on the right side between the barrier guard and light curtain transmitter. Also, the gap left at the front of the press between the press frame and light curtain sensing field allowing entry into the die area.
Recent events (2)
- — I (S) $1847.5
- — Z (S) $3695
1910.217 C05 I
- Issued
- Aug 29, 2019
- Abate by
- Oct 17, 2019
- Penalty
- Initial $11,934 · Current $5,967 Reduced
General-duty citation text
29 CFR 1910.217(c)(5)(i): Mechanical power press(es) where the operator feeds or removes parts by placing one or both hands in the point of operation, and a two hand control, presence sensing device, or type B gate or movable barrier guard is used, were not provided with a control system and brake monitor that complied with paragraphs (b) (13) and (14) of this section: A. Press Room: On, or about, June 17, 2019, Press 402, a Federal partial revolution mechanical power press, was provided with two hand controls for safeguarding. The press did not appear to have a brake monitor and other features to ensure control reliability such as, but not limited to, a self-checking dual air solenoid valve. C. Press Room: On, or about, June 17, 2019, Press 781, a South Bend partial revolution mechanical power press, was provided with two hand controls and light curtain for safeguarding. The press did not appear to have a brake monitor.
Recent events (2)
- — I (S) $5967
- — Z (S) $11934
1910.217 B07 IV B
- Issued
- Aug 29, 2019
- Abate by
- Oct 17, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(b)(7)(iv)(b): Being a single control protected against accidental actuation and so located that the worker cannot reach into the point of operation while operating the single control: Press Room: Press 364, a Havir Press Rite partial revolution mechanical power press, was provided with a single jog button that was not ringed or otherwise protected against accidental activation. Abatement Note: The control button appeared to be a re-purposed Top Stop button. The control button should be changed to a standard color and should be properly labeled.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.217 B07 V A
- Issued
- Aug 29, 2019
- Abate by
- Oct 17, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(b)(7)(v)(a): Each two-hand control for single stroke operations on mechanical power press(es) using part revolution clutches was not protected against unintended operation: Press Room: On, or about, June 17, 2019, the run/jog button provided on Press 334, a Walsh partial revolution mechanical power press, were not ringed or otherwise protected against accident contact.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.217 B07 XIII
- Issued
- Aug 29, 2019
- Abate by
- Oct 17, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(b)(7)(xiii): The clutch/brake control of mechanical power press(es) with part revolution clutches would not automatically deactivate in event of failure of the power or pressure supply for the clutch engaging means: Press Room: On, or about, June 17, 2019, the following partial revolution mechanical power presses were not provided with an air pressure switch: A. Press 399, Azimuth. B. Press 76, Azimuth. C. Press 364, Havir Press Rite.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.217 D09 II
- Issued
- Aug 29, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(d)(9)(ii): Spring loaded turnover bars were not provided for mechanical power press(es) designed to accept such turnover bars: Press Room: On, or about, June 10, 2019, a metal rod was used to bar Press 50, a Bliss partial revolution mechanical power press, during maintenance operations.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 335931)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344097688.