Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AIRFOIL IMPELLERS CORPORATION

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of AIRFOIL IMPELLERS CORPORATION in 2010 FOUNTAIN DRIVE, BRYAN, TX 77801 (NAICS 331524). OSHA activity number 344100060.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Airfoil Impellers Corporation — free Get an email when a new federal OSHA severe-injury report for Airfoil Impellers Corporation is published. One employer, no account, unsubscribe in one click.
Site address
2010 FOUNTAIN DRIVE
City
BRYAN
State
TX
ZIP
77801
Mailing
2010 FOUNTAIN DRIVE, BRYAN, TX 77801
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331524
Employees
24
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 3 instances 3 exposed
Issued
Aug 6, 2019
Abate by
Dec 22, 2019
Penalty
Initial $5,304 · Current $3,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On or about June 17, 2019 and times prior thereto, the employer did not effectively guard the following machines to protect the machine's operator, exposing employees to the hazard of coming in contact with moving machinery.    a) Drill presses in the machine shop used to drill holes in the center of the fan blade were not guarded to prevent employees from coming in contact with the moving drill bit or being struck by metal pieces.    b) The conveyor belt in the forge area used to move sand was not effectively guarded to prevent employees from coming in contact with the rotating shaft or the nip points created by the rollers.    c) The employees were operating the band-saw in the grinding area used to cut tubes used in the pouring of aluminum without the guard adjusted over the unused portion of the blade, exposing employees to hazards of being struck by the blade.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5304

1910.1200 G01

Other-than-serious 1 instance 15 exposed
Issued
Aug 6, 2019
Abate by
Sep 23, 2019
Penalty
Initial $2,273 · Current $0 Reduced
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use:    On or about June 16, 2019 and times prior thereto, the employer had not updated their hazard communication program to safety data sheets for employees working with or exposed to the following, but not limited to, chemicals: Olivine sand and aluminum.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2273

1904.29 B01

Other-than-serious 1 instance 1 exposed
Issued
Aug 6, 2019
Abate by
Aug 16, 2019
Penalty
Initial $758 · Current $0 Reduced
1904.29(b)(1):  A Log of all recordable work-related injuries and illnesses (OSHA Form 300 or equivalent) was not completed in the detail required by the regulation:    On or about June 17, 2019 and times prior to, the OSHA 300 Form for the calendar year 2019 did not include job titles for all entries.
Recent events (2)
  • — I (O) $0
  • — Z (O) $758

1910.134 C02 I

Other-than-serious 1 instance 3 exposed
Issued
Aug 6, 2019
Abate by
Aug 30, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  On or about June 17, 2019 and times prior thereto, the employer had not provided employees who voluntarily used N-95 respirators with the information contained in Appendix D, exposing employee to the hazards of inhalation.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344100060.