LUBBOCK, TX —
OSHA Inspection: LUPE QUINTANA
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of LUPE QUINTANA in 717 VENTOSO, LUBBOCK, TX 79401 (NAICS 238140). OSHA activity number 344100540.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LUPE QUINTANA
- Site address
- 717 VENTOSO
- City
- LUBBOCK
- State
- TX
- ZIP
- 79401
- Mailing
- 2716 BELVEDERE DR, LEVELLAND, TX 79336
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01
- Issued
- Dec 10, 2019
- Abate by
- Dec 30, 2019
- Penalty
- Initial $2,273 · Current $1,364 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) Employees were performing bricklaying activities from a scaffold structure that was not fully planked and were exposed to a fall off over 10 feet to the concrete below.
Recent events (2)
- — I (S) $1363.8
- — Z (S) $2273
1926.451 C02
- Issued
- Dec 10, 2019
- Abate by
- Dec 30, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: Employees performing bricklaying activities from a welded frame scaffold structure that did not have base plates in several locations and exposed to fall hazards of over 10 feet to the concrete below.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E01
- Issued
- Dec 10, 2019
- Abate by
- Dec 30, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. Employees engaged in bricklaying activities from the top level of a scaffold did not have a means of access or egress and were exposed to an unprotected fall in excess of ten feet to the ground below.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 F07
- Issued
- Dec 10, 2019
- Abate by
- Dec 30, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. Employees working from a scaffold structure that had not been erected under the supervision and direction of a competent person qualified in scaffold erection and were exposed to a fall of over 10 feet to the concrete below.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Dec 10, 2019
- Abate by
- Dec 30, 2019
- Penalty
- Initial $2,273 · Current $1,364 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): Employees engaged in bricklaying operations without fall protection were exposed to fall hazards in excess of six feet.
Recent events (2)
- — I (S) $1363.8
- — Z (S) $2273
More inspections in this industry (NAICS 238140)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344100540.