Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE EVANS FINDINGS COMPANY INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of THE EVANS FINDINGS COMPANY INC. in 33 EASTERN AVENUE, EAST PROVIDENCE, RI 02914 (NAICS 332119). OSHA activity number 344100722.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Evans Findings Company INC. — free Get an email when a new federal OSHA severe-injury report for The Evans Findings Company INC. is published. One employer, no account, unsubscribe in one click.
Site address
33 EASTERN AVENUE
City
EAST PROVIDENCE
State
RI
ZIP
02914
Mailing
33 EASTERN AVENUE, EAST PROVIDENCE, RI 02914
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332119
Employees
43
Ownership type
A

5 citations on file for this inspection.

1910.134 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 7, 2019
Abate by
Aug 30, 2019
Penalty
Initial $9,282 · Current $6,497 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  (a) Jobsite:  On or about 6/21/2019, the employer did not establish and implement a written respiratory protection program for an employee who wears a half-face 3M respirator while conducting work in the cleaning room.
Recent events (2)
  • — I (S) $6497.4
  • — Z (S) $9282

1910.134 D01 III

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 7, 2019
Abate by
Aug 30, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:  (a) Jobsite:  On or about 6/21/2019, the employer did not identify and evaluate the respiratory hazard(s) in the workplace for an employee who wears a half-face 3M respirator while conducting work in the cleaning room.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 7, 2019
Abate by
Aug 30, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  (a) Jobsite:  On or about 6/21/2019, the employer did not provide a medical evaluation for an employee before wearing a half- face 3M respirator that is required to conduct work in the cleaning room.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 7, 2019
Abate by
Aug 30, 2019
Penalty
Initial $6,630 · Current $4,641 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:  (a) Main building of operations:  On or about 6/21/2019, the employer did not remove metallic residues accumulated inside an electrical receptacle located behind a machine.
Recent events (2)
  • — I (S) $4641
  • — Z (S) $6630

1910.147 C04 II

Other-than-serious 1 instance 1 exposed
Issued
Aug 7, 2019
Abate by
Aug 30, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy.:  (a) Main building of operations:  On or about 6/21/2019, the employer had not developed and implemented specific energy control procedures for each machine in operation at the company.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View The Evans Findings Company INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344100722.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.