Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CONSOLIDATED DESIGN AND MACHINE, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of CONSOLIDATED DESIGN AND MACHINE, INC. in 501 PADEN ROAD, GADSDEN, AL 35903 (NAICS 236210). OSHA activity number 344106091.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Consolidated Design and Machine, INC. — free Get an email when a new federal OSHA severe-injury report for Consolidated Design and Machine, INC. is published. One employer, no account, unsubscribe in one click.
Site address
501 PADEN ROAD
City
GADSDEN
State
AL
ZIP
35903
Mailing
PO BOX 846, BOAZ, AL 35957
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236210
Employees
2
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 11, 2019
Abate by
Mar 14, 2022
Penalty
Initial $7,161 · Current $5,013 Reduced
OSH ACT of 1970 Section (5)(a)(1): : The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm in that employees were exposed to fall and struck-by hazards:  a) On or about June 11, 2019 - New Second Floor Box Room, employees and contractors were exposed to falls and struck-by hazards when the concrete thickness of the floor was changed from 6 inches, called for in the stamped drawing by the professional engineer, to approximately 9 inches thick without proper engineering evaluation of the existing structural framing. This reduced the allowable Live Load of the modified second floor and this may have contributed to the collapse of the second floor. The design change neither had approval from the professional engineer who stamped the design drawings nor was reviewed and stamped by another professional engineer.   Among other methods, one feasible and acceptable method to correct this hazard would be to ensure employees are following safe work practices such as informing the appropriate level manager of any structural modification(s) and complying with the Alabama State Board of Registration for Professional Engineers and Land Surveyors, Administrative Code, Chapter 33-X-11-03, Seals, Page 11-3, paragraph (5), and allow a Professional Engineer to evaluate, approve, provide the Professional Engineers stamp and signature on the drawings, then communicate the approved modification of all parties involved in the construction.
Recent events (3)
  • — J (S) $5013
  • — C (S) $7161
  • — Z (S) $7161

View Consolidated Design and Machine, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344106091.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.