Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MANZO ROOFING

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MANZO ROOFING in LOT 15 BLOCK 1 5550 STROMBOLI, MERIDIAN, ID 83642 (NAICS 238160). OSHA activity number 344109459.

Watch Manzo Roofing — free Get an email when a new federal OSHA severe-injury report for Manzo Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
MANZO ROOFING
Site address
LOT 15 BLOCK 1 5550 STROMBOLI
City
MERIDIAN
State
ID
ZIP
83642
Mailing
704 DUFUR ST, NAMPA, ID 83686
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
1
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2842.00 · Current $1500.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  (a)  An employee was exposed to fall hazards from up to an 18 feet high eave while engaged in shingle installation on a new single-family residential unit.  NOTE: Certification of corrective action is required for this item.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2842

1926.1053 B01

Serious Gravity 1 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $1705.00 · Current $750.00 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  (a)  An extension ladder used to access the lower roof level over the garage was not extended at least 3 feet above the landing surface.  The ladder extended only 1 rung above the landing surface.  NOTE: Certification of corrective action is required or this item.