Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MCLAUGHLIN'S TIMBER TRUCKING, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MCLAUGHLIN'S TIMBER TRUCKING, INC. in HAMMETT RD, ENFIELD, ME 04493 (NAICS 484220). OSHA activity number 344113279.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mclaughlin'S Timber Trucking, INC. — free Get an email when a new federal OSHA severe-injury report for Mclaughlin'S Timber Trucking, INC. is published. One employer, no account, unsubscribe in one click.
Site address
HAMMETT RD
City
ENFIELD
State
ME
ZIP
04493
Mailing
PO BOX 637, MEDWAY, ME 04460
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484220
Employees
4
Ownership type
A

7 citations on file for this inspection.

1910.176 B

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 9, 2019
Abate by
Oct 24, 2019
Penalty
Initial $3,978 · Current $1,989 Reduced
29 CFR 1910.176(b): Storage of material created a hazard:    Worksite - Felled trees were stacked too closely to overhead powerlines carrying 345,000 volts.
Recent events (2)
  • — I (S) $1989
  • — Z (S) $3978

1910.266 F01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 9, 2019
Abate by
Oct 24, 2019
Penalty
Initial $3,978 · Current $1,989 Reduced
29 CFR 1910.266(f)(1)(i): The employer did not ensure that each machine, including any machine provided by an employee, was maintained in a serviceable condition:    Worksite - The emergency stop pendant on the Morbark 50/48 was inoperable at the time of the inspection.
Recent events (2)
  • — I (S) $1989
  • — Z (S) $3978

1910.266 F08 I

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 9, 2019
Abate by
Oct 18, 2019
Penalty
Initial $3,978 · Current $1,989 Reduced
29 CFR 1910.266(f)(8)(i): Each machine was not equipped with guarding to protect employees from exposed moving elements, such as but not limited to, shafts, pulleys, belts on conveyors, and gears, in accordance with the requirements of subpart O of part 1910:    Worksite - The Morbark 50/48 chipper was missing a guard from the large sprocket and chain assembly on the right side of the machine.
Recent events (2)
  • — I (S) $1989
  • — Z (S) $3978

1910.266 I01

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 9, 2019
Abate by
Oct 18, 2019
Penalty
Initial $3,978 · Current $1,989 Reduced
29 CFR 1910.266(i)(1): The employer did not provide training for each employee, including supervisors, at no cost to the employee:    Worksite - The Employer did not provide training to satisfy the requirements of 1910.266(i)(3)(i) through 1910.266(i)(3)(iv) to the employee before allowing him to work on a logging operation.
Recent events (2)
  • — I (S) $1989
  • — Z (S) $3978

1910.266 D08 I

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 9, 2019
Abate by
Oct 24, 2019
Penalty
Initial $3,978 · Current $1,989 Reduced
29 CFR 1910.266(d)(8)(i): Logging operations near overhead electric lines were not done in accordance with the requirements of 29 CFR 1910.333(c)(3), in that the lines were not deenergized and grounded, nor were other protective measure provided before work was started:    Worksite - The Employer set up a temporary landing area near 345,000 volt overhead lines and did not protect employees from the exposure to electrical hazards.
Recent events (2)
  • — I (S) $1989
  • — Z (S) $3978

1910.266 D04

Other-than-serious 2 instances 1 exposed
Issued
Oct 9, 2019
Abate by
Oct 24, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.266(d)(4): The employer did not provide and maintain portable fire extinguishers on each machine and vehicle in accordance with the requirements of subpart L of part 1910:  Worksite - On or about June 27, 2019 two fire extinguishers, on the Morbark 50/48, had not been subjected to annual or monthly inspections IAW Subpart L of 29 CFR 1910.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.266 D08 II

Other-than-serious 1 instance 3 exposed
Issued
Oct 9, 2019
Abate by
Oct 18, 2019
Penalty
Initial $319 · Current $159 Reduced
29 CFR 1910.266(d)(8)(ii): The employer shall notify the power company immediately if a felled tree makes contact with any power line. Each employee shall remain clear of the area until the power company advises that there are no electrical hazards:    Worksite - The Employer did not contact the power company immediately after contacting the 345,000 volt overhead lines with felled trees at the landing site.
Recent events (2)
  • — I (O) $159
  • — Z (O) $319

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344113279.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.