CINCINNATI, OH ·
OSHA Inspection: STRUCTURAL SYSTEMS REPAIR GROUP, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of STRUCTURAL SYSTEMS REPAIR GROUP, LLC in 1724 VINE STREET, CINCINNATI, OH 45202 (NAICS 238110). OSHA activity number 344115753.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STRUCTURAL SYSTEMS REPAIR GROUP, LLC
- Site address
- 1724 VINE STREET
- City
- CINCINNATI
- State
- OH
- ZIP
- 45202
- Mailing
- 2824 STANTON AVE, WALNUT HILLS, OH 45206
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- Employees
- 129
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.451 F03
- Issued
- Aug 19, 2019
- Penalty
- Initial $11,934 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. On June 26, 2019, located on the north side of a commercial structure, employees were exposed to a fall hazard working from a framed tubular welded framed scaffold system as there were no inspections performed by a competent person prior to the work shift to ensure employees were protected from falling by installing a guardrail system, personal fall arrest system, or end rail systems. Potential fall height measured to be 14'-3".
Recent events (2)
- · I (S) $0
- · Z (S) $11934
1926.451 G01
- Issued
- Aug 19, 2019
- Penalty
- Initial $11,934 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. On June 26, 2019, located on the north side of a commercial structure, employees were not protected by falling while installing 2 X 4 lumber to the exterior structure working from a tubular welded frame scaffold system. Potential fall height measured to be 14'-3".