SAINT PETERSBURG, FL —
OSHA Inspection: MADICO, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MADICO, INC. in 2630 FAIRFIELD AVE SOUTH, SAINT PETERSBURG, FL 33712 (NAICS 326130). OSHA activity number 344115829.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MADICO, INC.
- Site address
- 2630 FAIRFIELD AVE SOUTH
- City
- SAINT PETERSBURG
- State
- FL
- ZIP
- 33712
- Mailing
- 9251 BELCHER ROAD NORTH, PINELLAS PARK, FL 33782
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326130
- Employees
- 207
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 II A
- Issued
- Nov 25, 2019
- Penalty
- Initial $11,934 · Current $11,934
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(A): The energy control procedures did not contain a specific statement on the intended use of the procedure: a. On or about June 17, 2019, at the jobsite on coating line two, the Lockout / Tagout program provided to employees operating the Nordson Extrusion Dies Industries (EDI) Ultracoat II Slot Die and the TEKNEK XWCH3 Wide Web Cleaner did not provide the employees a step-by-step procedure or direction on when a LOTO device is required, the purpose of the steps being performed, or how the procedure is protecting employees.
Recent events (2)
- — I (S) $11934
- — Z (S) $11934
1910.147 C06 I A
- Issued
- Nov 25, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i)(A): The periodic inspection of the energy control procedure was not performed by an authorized employee other than the one utilizing the energy control procedure being inspected: a. On or about June 26, 2019, the periodic inspection of the Lockout / Tagout program for the machinery on coating line two was conducted by employees who routinely work on coating line two and or whom performed routine maintenance on the machinery.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 II
- Issued
- Nov 25, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection: a. On or about June 26, 2019, the periodic inspection of the Lockout / Tagout program for the machinery on coating line dated 10/14/18 has the 001-902 written down for the LOTO number on the Periodic Inspection form and there are three names listed in the space for the Inspector. b. On or about June 26, 2019, the periodic inspection of the LOTO program for the machinery on coating line dated 12/21/17 does not have the equipment name and or Lockout / Tagout number listed on the Periodic Inspection forms.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Nov 25, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: a. On or about June 26, 2019, employees working on coating line two were not provided specific Lockout / Tagout (LOTO) training as to the location of power sources, type of LOTO devices required for machinery being serviced and or cleaned and methods of verifying the stored energy has been released, thus exposing employees to severe lacerations and amputations hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I D
- Issued
- Nov 25, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i)(D): Where tagout was used for energy control, the periodic inspection did not include a review between the inspector and each authorized and affected employee of the employee's responsibilities under the energy control procedure being inspected, and the elements set forth in paragraph (c)(7)(ii) of this section: a. On or about June 26, 2019, the periodic inspections from 2017 & 2018 of the Lockout / Tagout program for the machinery on coating line two was not conducted for each authorized employee that works and or performs maintenance on the machinery for coating line two.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Madico, INC.
View Madico, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326130)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344115829.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.