PALMYRA, NY —
OSHA Inspection: MWM VENTURES INC. DBA MODERN COATING & RESEARCH
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of MWM VENTURES INC. DBA MODERN COATING & RESEARCH in 400 EAST MAIN STREET, PALMYRA, NY 14522 (NAICS 332812). OSHA activity number 344117932.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MWM VENTURES INC. DBA MODERN COATING & RESEARCH
- Site address
- 400 EAST MAIN STREET
- City
- PALMYRA
- State
- NY
- ZIP
- 14522
- Mailing
- 400 EAST MAIN STREET, PALMYRA, NY 14522
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332812
- Employees
- 11
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.95 C01
- Issued
- Nov 22, 2019
- Abate by
- Dec 17, 2019
- Penalty
- Initial $4,546 · Current $2,955 Reduced
General-duty citation text
29 CFR 1910.95(c)(1): A continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (n) was not instituted when employee noise exposures equaled or exceeded an 8 hour time-weighted average sound level (TWA) of 85 dBA: a) Blast Room, on or about 7/18/19: Shot Blaster was exposed to continuous noise at a level of 215% of the dose of the OSHA permissible exposure limit. The equivalent dBA for the 215% dose is approximately 95.5 dBA calculated as the 8 hour time weighted sound pressure level. The sampling was conducted on 7/18/19 for 417 minutes. Exposure calculations include a zero increment for the 63 minutes not sampled. Employee was wearing ear plugs. Employer does not have a hearing conservation program implemented. Abatement methodology: Step 1: An effective hearing conservation program in accordance with 29 CFR 1910.95(c) through (n) shall be maintained. An effective hearing conservation program shall include, at a minimum: (1) A baseline audiogram for all employees exposed to noise levels equal to or in excess of the standard. (2) Annual audiograms for each overexposed employee. (3) analysis of audiogram results with retesting and/or referral to an otolaryngologist or qualified physician when a significant threshold shift occurs. A significant shift will be considered to be equal to or greater than an average of 30 dba over the 2000, 3000, and 4000 hertz frequencies. (4) Where insert ear plugs or custom-molded devices are utilized, individual employee fitting shall be conducted by a trained person, and employees shall be instructed in the care and use of the devices.
Recent events (2)
- — I (S) $2954.9
- — Z (S) $4546
1910.106 E06 I
- Issued
- Nov 22, 2019
- Penalty
- Initial $2,273 · Current $1,477 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(i): Adequate precautions against the ignition of flammable vapors were not taken: a) Paint Mixing Department, on or about 6/27/19: Employees dispensing Category 2 Flammable Liquid, Lacquer Thinner without grounding the 5 gallon containers.
Recent events (2)
- — I (S) $1477.45
- — Z (S) $2273
1910.106 E06 II
- Issued
- Nov 22, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Class I flammable liquid(s) were dispensed into containers without electrically interconnecting the nozzle and the container: a) Paint Mixing Department, on or about 6/27/19: Employees dispensing Category 2 Flammable Liquid, Lacquer Thinner from a 5 gallon container to a secondary container with no means of electrically interconnecting the nozzle and the portable container.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C01
- Issued
- Nov 22, 2019
- Abate by
- Dec 17, 2019
- Penalty
- Initial $2,273 · Current $2,955
General-duty citation text
29 CFR 1910.134(c)(1): Employer did not establish nor implement a written respiratory protection program with worksite specific procedures when respirators were necessary to protect the health of the employee or whenever respirators were required by the employer a) At the establishment, on or about 7/18/19: Employer had not established a written respiratory protection program when employees were required to wear half face air purifying respirators.
Recent events (2)
- — I (S) $2954.9
- — Z (S) $2273
1910.134 C02 I
- Issued
- Nov 22, 2019
- Penalty
- Initial $2,273 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(i): When voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in Appendix D to this section: a) Throughout the workplace, on or about 7/18/19: Employer allows voluntary use of dust masks and has not supplied employees with Appendix D of the respirator standard.
Recent events (2)
- — I (S) $0
- — Z (S) $2273
1910.134 E01
- Issued
- Nov 22, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Powder Coat Plant, on or about 6/27/19: Employees wear 3M and Honeywell half face air purifying respirators and had not been provided with a medical evaluation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F02
- Issued
- Nov 22, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employer did not ensure that an employee using a tight fitting facepiece respirator was fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) was used, and at least annually thereafter: a) Powder Coat Plant, on or about 6/27/19: Employees required to wear 3M and Honeywell half face air purifying respirators and had not been fit tested.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K
- Issued
- Nov 22, 2019
- Abate by
- Dec 17, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k) The employer did not provide effective, comprehensive, understandable, and annual (or more often if necessary) training to employees who are required to use respirators: a) At the establishment, on or about 7/18/19: Employees were required to wear half face air purifying respirators and had not received respirator training.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L01 I
- Issued
- Nov 22, 2019
- Penalty
- Initial $2,273 · Current $1,477 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) Work Floor, on or about 7/18/19: Operators of a Hyster Powered industrial truck were not provided with training.
Recent events (2)
- — I (S) $1477.45
- — Z (S) $2273
1910.242 B
- Issued
- Nov 22, 2019
- Penalty
- Initial $3,031 · Current $1,970 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) Small Powder Booth, on or about 6/27/19: Compressed air used for cleaning purposes measured at 95 p.s.i. b) Main Plant Paint Booth, on or about 6/27/19: Compressed air used for cleaning purposes measured at 53 p.s.i. c) 14' Powder Booth, on or about 6/27/19: Compressed air used for cleaning purposes measured at 69 p.s.i.
Recent events (2)
- — I (S) $1970.15
- — Z (S) $3031
1910.304 G05
- Issued
- Nov 22, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous and effective: a) Powder Coating Plant, on or about 6/27/19: Floor fan at the Hook Table had ground pin missing from plug end.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at MWM Ventures INC. DBA Modern Coating & Research
View MWM Ventures INC. DBA Modern Coating & Research's full OSHA safety record →