OSHA Inspection: U.S. CUSTOMS AND BORDER PROTECTION- BORDER PATROL- SPOKANE SECTOR

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. CUSTOMS AND BORDER PROTECTION- BORDER PATROL- SPOKANE SECTOR in 10710 N. NEWPORT HWY, SPOKANE, WA 99218 (NAICS 922120). OSHA activity number 344118302.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Customs and Border Protection- Border Patrol- Spokane Sector — free Get an email when a new federal OSHA severe-injury report for U.S. Customs and Border Protection- Border Patrol- Spokane Sector is published. One employer, no account, unsubscribe in one click.
Site address
10710 N. NEWPORT HWY
City
SPOKANE
State
WA
ZIP
99218
Mailing
10710 N. NEWPORT HWY, SPOKANE, WA 99218
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
922120
Employees
69
Ownership type
D

7 citations on file for this inspection.

1910.303 B02

Serious Gravity 1 6 instances 8 exposed
Issued
Aug 15, 2019
Abate by
Sep 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a)  U.S. Border Patrol at 10710 North Newport Highway, Spokane, WA; Intelligence/ Detention Building, Detention Area;  On or about June 26, 2019 and at time prior; A relocatable power tap (surge protector power strip) was plugged into another relocatable power tap which powered Dell computer equipment and electronic fingerprinting equipment.   (b)  Intelligence/ Detention Building, Room 219; On or about June 26, 2019 and at time prior;  A Sanyo refrigerator was plugged into a relocatable power tap (surge protector).   (c)  Intelligence/ Detention Building, Thunderdome Room; On or about June 26, 2019 and at time prior; A Keurig was plugged into a relocatable power tap (surge protector).   (d)  Intelligence/ Detention Building, Thunderdome Room; On or about June 26, 2019 and at time prior; A white relocatable power tap (surge protector) was plugged into another white relocatable power tap (surge protector), which powered Dell computer equipment.   (e)  Spokane Trailer;  On or about June 26, 2019 and at time prior; A Soleil heater was plugged into a relocatable tap (surge protector).   (f)  Special Projects Team Trailer;  On or about June 26, 2019 and at time prior; A microfridge stand alone microwave and a Westinghouse full size refrigerator was plugged into a relocatable power tap (surge protector).   The UL listing states that relocatable power taps are designed to be plugged into an outlet, and not daisy chained and plugged into other relocatable power taps or extension cords.  This exposes employees to possible electrical fire hazards.    The UL listing states that relocatable power taps are designed for low amperage computer and audiovisual types of equipment, and not appliances.  This exposes employees to possible electrical fire hazards.
Recent events (1)
  • — Z (S) $0

1910.37 B02

Other-than-serious 2 instances 6 exposed
Issued
Aug 15, 2019
Abate by
Aug 30, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  (a)    U.S. Border Patrol at 10710 North Newport Highway, Spokane, WA; Spokane Trailer; On or about June 26, 2019 and at time prior; Exit signs were not located over the exit discharge doors.   (b)    Special Projects Team Trailer;  On or about June 26, 2019 and at time prior;  Exit signs were not located over the exit discharge doors.
Recent events (1)
  • — Z (O) $0

1910.145 C02 I

Other-than-serious 1 instance 10 exposed
Issued
Aug 15, 2019
Abate by
Sep 4, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.145(c)(2)(i): Caution signs were not used to warn against potential hazards or to caution against unsafe practices:  (a)  U.S. Border Patrol at 10710 North Newport Highway, Spokane, WA; Administration Building, Gun Cleaning Area;  On or about June 26, 2019 and at time prior; Lead Caution signs were not posted to alert employees of the presence of lead and the precautions to take while performing tasks associated with gun cleaning.  This exposes employees to potential lead ingestion hazards.
Recent events (1)
  • — Z (O) $0

1910.157 C01

Other-than-serious 6 instances 10 exposed
Issued
Aug 15, 2019
Abate by
Sep 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  (a)  U.S. Border Patrol at 10710 North Newport Highway, Spokane, WA; Intelligence/ Detention Building Workout Room;  On or about June 26, 2019 and at time prior; A Sentry fire extinguisher was not mounted.   (b)  Intelligence/ Detention Building Bullpen;  On or about June 26, 2019 and at time prior; A Sentry fire extinguisher was not mounted.   (c)  Administration Building, Computer Server Room;  On or about June 26, 2019 and at time prior; Two carbon dioxide fire extinguishers were sitting on the floor- not mounted.  (d)  Intelligence/ Detention Building Workout Room; On or about June 26, 2019 and at time prior; A Sentry fire extinguisher was not mounted.   (e)  Intelligence/ Detention Building Bullpen;  On or about June 26, 2019 and at time prior; A Sentry fire extinguisher was not mounted.   (f)  Administration Building, Computer Server Room; On or about June 26, 2019 and at time prior; Two carbon dioxide fire extinguishers were sitting on the floor- not mounted. This exposes employees to possible tripping and/or struck by hazards.
Recent events (1)
  • — Z (O) $0

1910.303 G01 I

Other-than-serious 1 instance 3 exposed
Issued
Aug 15, 2019
Abate by
Sep 4, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(i): Work space was less than 30 inches wide in front of electric equipment operating at 600 volts, nominal, or less:   (a)    U.S. Border Patrol at 10710 North Newport Highway, Spokane, WA; Administration Building/ Logistics Room;  On or about June 26, 2019 and at time prior; Electrical Panel G had a shelving unit located approximately 23 inches from the panel.
Recent events (1)
  • — Z (O) $0

1910.303 G01 II

Other-than-serious 2 instances 3 exposed
Issued
Aug 15, 2019
Abate by
Aug 27, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  (a)  U.S. Border Patrol at 10710 North Newport Highway, Spokane, WA; Administration Building/ Logistics Room;  On or about June 26, 2019 and at time prior; Electrical Panel G had floor mats stored underneath  it and a shelving unit was located approximately 23 inches from the panel.     (b)  Administration Building, Computer Server Room; On or about June 26, 2019 and at time prior; A swifter, broom, spool of wire, Avaya box and Panduit box were stored underneath the breaker panel for the room.  CORRECTED DURING INSPECTION
Recent events (1)
  • — Z (O) $0

1910.1200 G08

Other-than-serious 1 instance 40 exposed
Issued
Aug 15, 2019
Abate by
Sep 4, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8):   The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work  shift to employees when they were in their work area(s):  (a)       U.S. Border Patrol at 10710 North Newport Highway, Spokane, WA; Administration Building; On or about June 26, 2019 and at time prior; The employer did not have safety data sheets for ammunition that officers carry on their person which includes:  Federal EX40HC ammunition, Winchester Q3340 ammunition, Winchester Ranger 9mm luger ammunition, and paint pellets with and without tear gas.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344118302.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.