WESTON, FL —
OSHA Inspection: R.R.P. CONCRETE SERVICES INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of R.R.P. CONCRETE SERVICES INC. in 2944 LAKE RIDGE LN LOT #4, WESTON, FL 33332 (NAICS 238170). OSHA activity number 344121421.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- R.R.P. CONCRETE SERVICES INC.
- Site address
- 2944 LAKE RIDGE LN LOT #4
- City
- WESTON
- State
- FL
- ZIP
- 33332
- Mailing
- 246 NW 14TH STREET, HOMESTEAD, FL 33030
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 7
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01 I
- Issued
- Nov 1, 2019
- Abate by
- Nov 8, 2019
- Penalty
- Initial $3,031 · Current $1,516 Reduced
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. On or about 6/27/2019, at 2944 Lake Ridge Ln, Lot #4, Weston FL 33332, employees worked from tubular welded scaffolds that were not fully planked, which exposed employees to a fall hazard of approximately 6' to a lower level.
Recent events (2)
- — I (S) $1515.5
- — Z (S) $3031
1926.451 C02
- Issued
- Nov 1, 2019
- Abate by
- Nov 8, 2019
- Penalty
- Initial $3,031 · Current $1,516 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: On or about 6/27/2019, at 2944 Lake Ridge Ln, Lot #4, Weston FL 33332, employees worked from tubular welded scaffolds that lacked baseplates and were supported by concrete blocks, which exposed employees to a fall hazard of approximately 6' to a lower level.
Recent events (2)
- — I (S) $1515.5
- — Z (S) $3031
1926.452 C02
- Issued
- Nov 1, 2019
- Abate by
- Nov 8, 2019
- Penalty
- Initial $3,031 · Current $1,516 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: On or about 6/27/2019, at 2944 Lake Ridge Ln, Lot #4, Weston FL 33332, employees worked from tubular welded scaffolds that lacked crossbrases, which exposed employees to a fall hazard of approximately 6' to a lower level.
Recent events (2)
- — I (S) $1515.5
- — Z (S) $3031
1926.501 B13
- Issued
- Nov 1, 2019
- Penalty
- Initial $5,304 · Current $2,652 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: On or about 6/27/2019, at 2944 Lake Ridge Ln, Lot #4, Weston FL 33332, employees were installing roof decking without being protected from falling a distance of 10 feet to ground level with an acceptable fall protection method.
Recent events (2)
- — I (S) $2652
- — Z (S) $5304
1926.1053 B01
- Issued
- Nov 1, 2019
- Penalty
- Initial $5,304 · Current $2,652 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: On or about 6/27/2019, at 2944 Lake Ridge Ln, Lot #4, Weston FL 33332, employees were exposed to a fall hazard of 10'-0" while accessing an area of the roof using an extension ladder (i.e. Louisville, 16 feet) extending 1 foot approximately above landing surface.