AMESBURY, MA —
OSHA Inspection: VALIANT INDUSTRIES, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of VALIANT INDUSTRIES, INC. in 12 MERRILL STREET, AMESBURY, MA 01913 (NAICS 337212). OSHA activity number 344122502.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VALIANT INDUSTRIES, INC.
- Site address
- 12 MERRILL STREET
- City
- AMESBURY
- State
- MA
- ZIP
- 01913
- Mailing
- 12 MERRILL STREET, AMESBURY, MA 01913
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337212
- Employees
- 16
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.95 C01
- Issued
- Sep 30, 2019
- Abate by
- Dec 31, 2019
- Penalty
- Initial $5,304 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: Location: Milling area On or about August 28, 2019, an employee was exposed to noise levels exceeding the 8-hour time-weighted average (TWA) of 85dBA while operating the milling machines. The employee was exposed to continuous noise level of 88.4dB as an 8-hour Time-Weighted Average (TWA), which was the equivalent to 74.6% of the permissible daily noise exposure during 441 minutes sampling period and zero exposure was assumed for the un-sampled time period. A hearing conservation program was not developed or implemented for the sampled employee.
Recent events (2)
- — I (S) $2500
- — Z (S) $5304
1910.95 G01
- Issued
- Sep 30, 2019
- Abate by
- Dec 31, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.95(g)(1): The employer did not establish and maintain an audiometric testing program as provided by 29 CFR 1910.95(g) by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels: Location: Milling area On or about August 28, 2019, an employee was exposed to noise levels exceeding the 8-hour time-weighted average (TWA) of 85dBA while operating the milling machines. The employee was exposed to continuous noise level of 88.4dB as an 8-hour Time-Weighted Average (TWA), which was the equivalent to 74.6% of the permissible daily noise exposure during 441 minutes sampling period and zero exposure was assumed for the un-sampled time period. Audiometric testing was not implemented for employees exceeding the action level of 50% permissible daily noise exposure.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 D06
- Issued
- Sep 30, 2019
- Abate by
- Dec 31, 2019
- Penalty
- Initial $3,789 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.107(d)(6): Belts. Belts shall not enter the duct or booth unless the belt and pulley within the duct or booth are thoroughly enclosed. Location: Spray room On or about July 1, 2019, two belts which were part of the exhaust fan's engine were not thoroughly enclosed.
Recent events (2)
- — I (S) $1800
- — Z (S) $3789
1910.107 D05
- Issued
- Sep 30, 2019
- Abate by
- Dec 31, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(d)(5): Electric motor driving exhaust fan for spray booth were located inside the booth. Location: Spraybooth area On or about July 1, 2019, an electric motor powered a BINKS 83 2448 exhaust fan for the spraybooth was located inside the booth.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 E01
- Issued
- Sep 30, 2019
- Abate by
- Nov 29, 2019
- Penalty
- Initial $3,031 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: Note: The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator. Location: Spray Booth On or about July 1, 2019, medical evaluations were not conducted to determine an employee's ability to use a tight fitting half-face 3M respirator.
Recent events (2)
- — I (S) $1000
- — Z (S) $3031
1910.134 D01 III
- Issued
- Sep 30, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form. Location: Spray Booth On or about July 1, 2019, respiratory hazards resulting from Butyl Acetate were not evaluated in the workplace.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1904.4 A
- Issued
- Sep 30, 2019
- Abate by
- Oct 18, 2019
- Penalty
- Initial $758 · Current $300 Reduced
General-duty citation text
29 CFR 1904.4(a): The employer did not record each work-related fatality, injury or illness case that resulted in the general recording criteria on the OSHA Form 300 or equivalent. Location: Office On or about July 1, 2019, a work-related injury case was not recorded on the 2019 OSHA 300 log.
Recent events (2)
- — I (O) $300
- — Z (O) $758
1910.134 K06
- Issued
- Sep 30, 2019
- Abate by
- Oct 18, 2019
- Penalty
- Initial $425 · Current $200 Reduced
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer. Location: Facility On or about July 1, 2019, employees voluntarily donning filtering face piece respirators were not provided basic advisory information found in Appendix D prior to utilizing the respirators.
Recent events (2)
- — I (O) $200
- — Z (O) $425
More inspections at Valiant Industries, INC.
View Valiant Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337212)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344122502.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.