CHICAGO, IL —
OSHA Inspection: NATIONAL OFFICE LIQUIDATORS, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NATIONAL OFFICE LIQUIDATORS, LLC in 4350 N KNOX AVE, CHICAGO, IL 60641 (NAICS 337214). OSHA activity number 344126537.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATIONAL OFFICE LIQUIDATORS, LLC
- Site address
- 4350 N KNOX AVE
- City
- CHICAGO
- State
- IL
- ZIP
- 60641
- Mailing
- 4350 N KNOX AVE, CHICAGO, IL 60641
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337214
- Employees
- 5
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Nov 15, 2019
- Abate by
- Dec 12, 2019
- Penalty
- Initial $2,273 · Current $2,273
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by and crush-by hazards: a) Warehouse - On July 2, 2019, the employer failed to anchor and bolt down storage racks to prevent employees from exposure to struck-by and/or crushing hazards when moving boxes weighing approximately 200 pounds using pallet jacks. Among other methods, one feasible and acceptable method to correct the hazards noted are to follow the manufacturer installation instructions and/or conform with installation and assembly instructions and the American National Standards Institute (ANSI) standard MH16.1-2012 (a revision of MH16.1-2008): Specifications for the Design, Testing and Utilization of Industrial Steel Storage Racks, which includes, among others, the following: a. Section 1.4.7 Column Base Plates and Anchors: The bottom of all columns shall be furnished with column base plates, as specified in 7.1. All rack columns shall be anchored to the floor with anchor bolts, which shall be designed in accordance with Section 7.3, to resist all applicable forces as described in Section 2.1 or Section 2.2. b) Warehouse - On July 2, 2019, the employer did not ensure that the two level storage rack system with multiple bays used to store pallets of materials weighing 1510-3000 lbs., displayed plaques with rated loads (1.4.2 plaque); b. Section 1.4.2 Plaque: The owner is responsible for displaying in one or more conspicuous locations permanent plaque(s). Each plaque shall have an area of not less than 50 inches. Plaques shall show in clear, legible print (a) the maximum permissible unit load and/or maximum uniformly distributed load per level, (b) the average unit load, and (c) maximum total load per bay.
Recent events (1)
- — Z (S) $2273
More inspections in this industry (NAICS 337214)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344126537.