Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: STRUCTURAL FABRICATION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STRUCTURAL FABRICATION, INC. in 111 CODY LN., SHERMAN, TX 75092 (NAICS 332312). OSHA activity number 344128285.

Watch Structural Fabrication, INC. — free Get an email when a new federal OSHA severe-injury report for Structural Fabrication, INC. is published. One employer, no account, unsubscribe in one click.
Site address
111 CODY LN.
City
SHERMAN
State
TX
ZIP
75092
Mailing
111 CODY LN., SHERMAN, TX 75092
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
21
Ownership type
A

5 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $2576.00 · Current $1546.00 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by a rotating blade.   On the east wall, the employer did not ensure the blade of the evolution cutting machine guard lowered when cutting.  The employer had the guard bolted in the up position exposing employees to amputation hazards.
Recent events (2)
  • — I (S) $1545.6
  • — Z (S) $2576

1910.213 I01

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $3220.00 · Current $1932.00 Reduced
29 CFR 1910.213(i)(1): Nonworking portion(s) of the blade of the bandsaw were not enclosed or guarded.   On the east side of the production area, employees operated a metal cutting band saw and the unused portion of the blade was not guarded exposing employees to amputation hazards.  Approximately 12 inches of the blade was unguarded.
Recent events (2)
  • — I (S) $1932
  • — Z (S) $3220

1910.334 A02 I

Serious Gravity 1 1 instance 4 exposed
Issued
Penalty
Initial $1932.00 · Current $1159.00 Reduced
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket).    On the south side of the production area, the employees used a floor fan and the power cord outer sheathing was split exposing internal wiring.  The employees were exposed to electrical shock hazards.
Recent events (2)
  • — I (S) $1159.2
  • — Z (S) $1932

1910.305 B03 II

Other-than-serious 1 instance 4 exposed
Issued
Penalty
Initial $361.00 · Current $217.00 Reduced
29 CFR 1910.305(b)(3)(ii): 29 CFR 1910.305(b)(3)(ii): Boxes shall be closed by suitable covers securely fastened in place, boxes were not closed as required.    On the west side of the production area, the employer did not ensure the electrical panel box used to energize machinery and lights were effectively closed during operations.  The employees were exposed to electrical shock hazards and inadvertent energization of equipment.
Recent events (2)
  • — I (O) $216.6
  • — Z (O) $361

1910.304 F01 VIII

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $425.00 · Current $255.00 Reduced
29 CFR 1910.304(f)(1)(viii): Circuit breakers used as switches in 120-volt and 277-volt, fluorescent lighting circuits were not listed and marked "SWD."   On the west side of the production area, the employer allowed employees to turn fluorescent lights on and off from the electrical panel box and circuits that were not listed and marked "SWD".  The employees were exposed to electrical shock hazards.
Recent events (2)
  • — I (O) $255
  • — Z (O) $425

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344128285.