BROOKLYN, NY —
OSHA Inspection: SBT PLUMBING & HEATING INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of SBT PLUMBING & HEATING INC. in 501 MYRTLE AVENUE, BROOKLYN, NY 11205 (NAICS 238220). OSHA activity number 344131271.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SBT PLUMBING & HEATING INC.
- Site address
- 501 MYRTLE AVENUE
- City
- BROOKLYN
- State
- NY
- ZIP
- 11205
- Mailing
- 131-06 40TH RD. 3RD FLOOR, FLUSHING, NY 11354
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.404 F06
- Issued
- Dec 23, 2019
- Abate by
- Jan 2, 2020
- Penalty
- Initial $3,031 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: Location: 501 Myrtle Avenue, Brooklyn, NY 11205 On or about: 07/01/2019 (a) A Hilti TE 905-AVR used to break concrete was missing the ground pin. (b) An extension cord used to energize power tools was missing the ground pin.
Recent events (3)
- — F (S) $2000
- — C (S) $3031
- — Z (S) $3031
1926.405 G02 IV
- Issued
- Dec 23, 2019
- Abate by
- Jan 2, 2020
- Penalty
- Initial $3,031 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: Location: 501 Myrtle Avenue, Brooklyn, NY 11205 On or about: 07/01/2019 (a) The employer did not ensure that strain relief was provide to the extension cord used to power a Hilti TE 905-AVR used to break concrete; the extension cord had strain damage exposing the internal wire insulation.
Recent events (3)
- — F (S) $2000
- — C (S) $3031
- — Z (S) $3031
1926.1052 B01
- Issued
- Dec 23, 2019
- Abate by
- Jan 6, 2020
- Penalty
- Initial $3,031 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.1052(b)(1): Foot traffic was not prohibited on stairways where the treads and/or landings of pan stairs were to be filled in with concrete or other material at a later date and stairs were not temporarily fitted with wood or other solid material at least to the top edge of each pan. Location: 501 Myrtle Avenue, Brooklyn, NY 11205 On or about: 07/01/2019 (a) The treads of the stairway between the ground floor and the basement level were not temporarily filled or fitted with wood or other solid materials at least to the top edge of each pan. Employees performing plumbing on the basement level used the stairway to travel between the ground floor and the basement level.
Recent events (3)
- — F (S) $2000
- — C (S) $3031
- — Z (S) $3031
More inspections at SBT Plumbing & Heating INC.
View SBT Plumbing & Heating INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238220)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344131271.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.