DALLAS, TX —
OSHA Inspection: RICARDO SANCHEZ
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of RICARDO SANCHEZ in 7006 BRIAR COVE DRIVE, DALLAS, TX 75354 (NAICS 238170). OSHA activity number 344133673.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RICARDO SANCHEZ
- Site address
- 7006 BRIAR COVE DRIVE
- City
- DALLAS
- State
- TX
- ZIP
- 75354
- Mailing
- 7594 REMINGTON ROAD, MANSFIELD, TX 76063
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.416 A01
- Issued
- Nov 22, 2019
- Abate by
- Jul 8, 2020
- Penalty
- Initial $3,978 · Current $1,550 Reduced
General-duty citation text
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: (a) On or about July 5, 2019 and times prior thereto; employees detaching metal gutters in proximity to an overhead powerline were exposed to electrocution hazards.
Recent events (3)
- — F (S) $1550
- — C (S) $3978
- — Z (S) $3978
1926.416 A03
- Issued
- Nov 22, 2019
- Abate by
- Jul 8, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(a)(3): When and where energized circuits existed, the employer failed to post and maintain proper warning signs, advise employees of the location, hazard involved and the proper protective measures to be taken: (a) On or about July 5, 2019 and times prior thereto employees were exposed to electrocution hazards when working near energized overhead powerlines.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Nov 22, 2019
- Abate by
- Jul 8, 2020
- Penalty
- Initial $3,978 · Current $1,550 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: (a) On or about July 5, 2019 and times prior thereto; an employee was exposed to the hazard of falling 9-feet to the ground below.
Recent events (3)
- — F (S) $1550
- — C (S) $3978
- — Z (S) $3978
1926.1053 B12
- Issued
- Nov 22, 2019
- Abate by
- Jul 8, 2020
- Penalty
- Initial $3,978 · Current $1,550 Reduced
General-duty citation text
29 CFR 1926.1053(b)(12): Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive siderails: (a) On or about July 5, 2019 and times prior thereto employees used an aluminum extension ladder that did not have nonconductive siderails. Employees were exposed to electrocution hazards.
Recent events (3)
- — F (S) $1550
- — C (S) $3978
- — Z (S) $3978
1926.1060 A
- Issued
- Nov 22, 2019
- Abate by
- Jul 8, 2020
- Penalty
- Initial $3,978 · Current $1,550 Reduced
General-duty citation text
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards. (a) On or about July 15, 2019 and times prior thereto employees were using a metal extension ladder near an overhead energized powerline. Employees were exposed to electrocution hazards.
Recent events (3)
- — F (S) $1550
- — C (S) $3978
- — Z (S) $3978
More inspections at Ricardo Sanchez
View Ricardo Sanchez's full OSHA safety record →
More inspections in this industry (NAICS 238170)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344133673.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.