TAUNTON, MA —
OSHA Inspection: AMERICAN INSULATED PANEL COMPANY, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AMERICAN INSULATED PANEL COMPANY, INC in 75 JOHN HANCOCK ROAD, TAUNTON, MA 02780 (NAICS 333415). OSHA activity number 344135595.
Where did this inspection happen?
- Establishment
- AMERICAN INSULATED PANEL COMPANY, INC
- Site address
- 75 JOHN HANCOCK ROAD
- City
- TAUNTON
- State
- MA
- ZIP
- 02780
- Mailing
- 75 JOHN HANCOCK ROAD, TAUNTON, MA 02780
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333415
- Employees
- 33
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.179 J04 I
- Issued
- Sep 26, 2019
- Abate by
- Nov 18, 2019
- Penalty
- Initial $2,984 · Current $2,089 Reduced
General-duty citation text
29 CFR 1910.179(j)(4)(i): Crane(s) which were idle for a period of one month or more, but less than six months, were not given an inspection conforming with the requirements of 1910.179(j)(2) and 1910.179(m)(2) before being placed into service: Location: Lamination/National Panel Area. Employer failed to conduct inspections of a five (5) ton gantry crane, used on a monthly basis.
Recent events (2)
- — I (S) $2088.8
- — Z (S) $2984
1910.219 F03
- Issued
- Sep 26, 2019
- Abate by
- Nov 18, 2019
- Penalty
- Initial $3,978 · Current $2,785 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: Location: National Panel/Lamination Area. Employees were exposed to potential caught-by hazards while working near the National Panel lamination machine where the chain drive for the glue pump was not guarded.
Recent events (2)
- — I (S) $2784.6
- — Z (S) $3978
More inspections at American Insulated Panel Company, INC
View American Insulated Panel Company, INC's full OSHA safety record →
More inspections in this industry (NAICS 333415)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344135595.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.